CivilAxisCivilAxis
☕ Support🌐 Community

SHS 180×180×8 - Section Properties

The SHS 180×180×8 is a square hollow section with a mass of 42.7 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 8 mm. It has a cross-sectional area of 54.4 cm², a second moment of area Iᵧ of 2660 cm⁴, a plastic modulus Wₚₗ,ᵧ of 349 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
42.7 kg/m
Depth
180 mm
Width
180 mm
Wall thickness
8 mm
Area
54.4 cm²
Ask about capacity, buckling or detailing for SHS 180×180×8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 180×180×8

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 180×180×8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh180
Width of sectionb180
Wall thicknesst8

Mass and area

Mass per metremass42.7
Cross-sectional areaA54.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2660
Elastic section modulus about y-axisWel,y296
Plastic section modulus about y-axisWpl,y349
Radius of gyration about y-axisiy7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2660
Elastic section modulus about z-axisWel,z296
Plastic section modulus about z-axisWpl,z349
Radius of gyration about z-axisiz7

Torsion and warping

Torsion constant (St Venant)It4160
Section modulus for torsionWt434

Surface area

Surface area per metreSA/m0.699
Surface area per tonneSA/t16.4m²/t

Is SHS 180×180×8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
39.0 / 123.9 kNm
Shear8%
44.6 / 557.5 kN
Deflection61%
5.9 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 180×180×8

SHS 180×180×8 has a mass of 42.7 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 512 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 180×180×8 has a depth of 180 mm, a width of 180 mm, a wall thickness of 8 mm, with a cross-sectional area of 54.4 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 349 cm³, and the elastic modulus Wel,y is 296 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 124 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,660 cm⁴, and about the minor axis Iz is 2,660 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7 cm about the major axis and iz is 7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,160 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 160×160×16SHS 180×180×5SHS 180×180×6.3SHS 180×180×7.1SHS 180×180×8.8SHS 180×180×10SHS 180×180×12.5SHS 180×180×14.2

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 180×180×8vs SHS 175×175×9

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…