CivilAxisCivilAxis
☕ Support🌐 Community

SHS 200×200×14.2 - Section Properties

The SHS 200×200×14.2 is a square hollow section with a mass of 81.1 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 14.2 mm. It has a cross-sectional area of 103 cm², a second moment of area Iᵧ of 5870 cm⁴, a plastic modulus Wₚₗ,ᵧ of 714 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
81.1 kg/m
Depth
200 mm
Width
200 mm
Wall thickness
14.2 mm
Area
103 cm²
Ask about capacity, buckling or detailing for SHS 200×200×14.2.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 200×200×14.2

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 200×200×14.2 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh200
Width of sectionb200
Wall thicknesst14.2

Mass and area

Mass per metremass81.1
Cross-sectional areaA103

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5870
Elastic section modulus about y-axisWel,y587
Plastic section modulus about y-axisWpl,y714
Radius of gyration about y-axisiy7.54

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz5870
Elastic section modulus about z-axisWel,z587
Plastic section modulus about z-axisWpl,z714
Radius of gyration about z-axisiz7.54

Torsion and warping

Torsion constant (St Venant)It9420
Section modulus for torsionWt854

Surface area

Surface area per metreSA/m0.763
Surface area per tonneSA/t9.38m²/t

Is SHS 200×200×14.2 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending30%
75.0 / 253.5 kNm
Shear7%
75.0 / 1055.5 kN
Deflection61%
6.8 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 200×200×14.2

SHS 200×200×14.2 has a mass of 81.1 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 973 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 200×200×14.2 has a depth of 200 mm, a width of 200 mm, a wall thickness of 14.2 mm, with a cross-sectional area of 103 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 714 cm³, and the elastic modulus Wel,y is 587 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 253 kNm before any stability check.

The second moment of area about the major axis, Iy, is 5,870 cm⁴, and about the minor axis Iz is 5,870 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.54 cm about the major axis and iz is 7.54 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.54 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9,420 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 200×200×8SHS 200×200×8.8SHS 200×200×10SHS 200×200×12.5SHS 200×200×16SHS 250×250×5SHS 250×250×6.3SHS 250×250×7.1

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section