SHS 200×200×10 - Section Properties
The SHS 200×200×10 is a square hollow section with a mass of 58.8 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 10 mm. It has a cross-sectional area of 74.9 cm², a second moment of area Iᵧ of 4470 cm⁴, a plastic modulus Wₚₗ,ᵧ of 531 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for SHS 200×200×10.
or pick a unit on any row

Dimension symbols for SHS Hot-finished sections. Not to scale.
Is SHS 200×200×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending30%
57.0 / 188.5 kNmShear7%
57.0 / 767.6 kNDeflection61%
6.7 / 11.1 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 200×200×10
Related SHS Hot-finished sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…