CivilAxisCivilAxis
☕ Support🌐 Community

SHS 200×200×6.3 - Section Properties

The SHS 200×200×6.3 is a square hollow section with a mass of 38 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 48.4 cm², a second moment of area Iᵧ of 3010 cm⁴, a plastic modulus Wₚₗ,ᵧ of 350 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
38 kg/m
Depth
200 mm
Width
200 mm
Wall thickness
6.3 mm
Area
48.4 cm²
Ask about capacity, buckling or detailing for SHS 200×200×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 200×200×6.3

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 200×200×6.3 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh200
Width of sectionb200
Wall thicknesst6.3

Mass and area

Mass per metremass38
Cross-sectional areaA48.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3010
Elastic section modulus about y-axisWel,y301
Plastic section modulus about y-axisWpl,y350
Radius of gyration about y-axisiy7.89

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3010
Elastic section modulus about z-axisWel,z301
Plastic section modulus about z-axisWpl,z350
Radius of gyration about z-axisiz7.89

Torsion and warping

Torsion constant (St Venant)It4650
Section modulus for torsionWt444

Surface area

Surface area per metreSA/m0.784
Surface area per tonneSA/t20.6m²/t

Is SHS 200×200×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending31%
39.0 / 124.3 kNm
Shear8%
39.0 / 496.0 kN
Deflection62%
6.9 / 11.1 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 200×200×6.3

SHS 200×200×6.3 has a mass of 38 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 456 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 200×200×6.3 has a depth of 200 mm, a width of 200 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 48.4 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 350 cm³, and the elastic modulus Wel,y is 301 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 124 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,010 cm⁴, and about the minor axis Iz is 3,010 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.89 cm about the major axis and iz is 7.89 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.89 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,650 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 180×180×12.5SHS 180×180×14.2SHS 180×180×16SHS 200×200×5SHS 200×200×7.1SHS 200×200×8SHS 200×200×8.8SHS 200×200×10

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 200×200×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…