CivilAxisCivilAxis
☕ Support🌐 Community

SHS 350×350×12.5 - Section Properties

The SHS 350×350×12.5 is a square hollow section with a mass of 131 kg/m, an overall depth of 350 mm and width of 350 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 167 cm², a second moment of area Iᵧ of 31500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2110 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
131 kg/m
Depth
350 mm
Width
350 mm
Wall thickness
12.5 mm
Area
167 cm²
Ask about capacity, buckling or detailing for SHS 350×350×12.5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 350×350×12.5

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 350×350×12.5 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh350
Width of sectionb350
Wall thicknesst12.5

Mass and area

Mass per metremass131
Cross-sectional areaA167

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy31500
Elastic section modulus about y-axisWel,y1800
Plastic section modulus about y-axisWpl,y2110
Radius of gyration about y-axisiy13.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz31500
Elastic section modulus about z-axisWel,z1800
Plastic section modulus about z-axisWpl,z2110
Radius of gyration about z-axisiz13.7

Torsion and warping

Torsion constant (St Venant)It48900
Section modulus for torsionWt2650

Surface area

Surface area per metreSA/m1.37
Surface area per tonneSA/t10.4m²/t

Is SHS 350×350×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
229.7 / 749.0 kNm
Shear8%
131.3 / 1711.4 kN
Deflection61%
11.8 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 350×350×12.5

SHS 350×350×12.5 has a mass of 131 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 1572 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 350×350×12.5 has a depth of 350 mm, a width of 350 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 167 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,110 cm³, and the elastic modulus Wel,y is 1,800 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 749 kNm before any stability check.

The second moment of area about the major axis, Iy, is 31,500 cm⁴, and about the minor axis Iz is 31,500 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 13.7 cm about the major axis and iz is 13.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 13.7 cm a 1.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 48,900 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 300×300×16SHS 350×350×8SHS 350×350×8.8SHS 350×350×10SHS 350×350×14.2SHS 350×350×16SHS 400×400×8SHS 400×400×8.8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 350×350×12.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…