CivilAxisCivilAxis
☕ Support🌐 Community

SQ 13 - Section Properties

The SQ 13 is a steel section with a mass of 1.33 kg/m, an overall depth of 13 mm and width of 13 mm. It has a cross-sectional area of 1.7 cm², a second moment of area Iᵧ of 0.238 cm⁴, a plastic modulus Wₚₗ,ᵧ of 0.5493 cm³, tabulated by CivilAxis from EN 10059 · Continental Steel.

Mass
1.33 kg/m
Depth
13 mm
Width
13 mm
Area
1.7 cm²
Ask about capacity, buckling or detailing for SQ 13.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SQ 13 section properties to EN 10059 · Continental Steel.

Geometry

Depth of sectionh13
Width of sectionb13

Mass and area

Mass per metremass1.33
Cross-sectional areaA1.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy0.238
Elastic section modulus about y-axisWel,y0.3662
Plastic section modulus about y-axisWpl,y0.5493
Radius of gyration about y-axisiy0.38

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz0.238
Elastic section modulus about z-axisWel,z0.3662
Plastic section modulus about z-axisWpl,z0.5493
Radius of gyration about z-axisiz0.38

Common questions about SQ 13

SQ 13 has a mass of 1.33 kg/m, tabulated to EN 10059. A 12 m length therefore weighs about 16 kg, which is the figure to use for a steel take-off or when checking a lift.

SQ 13 has a depth of 13 mm, a width of 13 mm, with a cross-sectional area of 1.7 cm². These are the nominal dimensions from EN 10059; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 0.549 cm³, and the elastic modulus Wel,y is 0.366 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 0 kNm before any stability check.

The second moment of area about the major axis, Iy, is 0.238 cm⁴, and about the minor axis Iz is 0.238 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 0.38 cm about the major axis and iz is 0.38 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 0.38 cm a 0.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Square Bar sizes

SQ 9SQ 10SQ 12SQ 16SQ 18SQ 19SQ 22SQ 25

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Square Bar sizes
Square Bars
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…