CivilAxisCivilAxis
☕ Support🌐 Community

TFC 75x40x5 - Section Properties

The TFC 75x40x5 is a tapered flange channel with a mass of 6.92 kg/m. It has a cross-sectional area of 8.82 cm², a second moment of area Iᵧ of 75.9 cm⁴, an elastic modulus Wₑₗ,ᵧ of 20.2 cm³, tabulated by CivilAxis from Continental Steel.

Mass
6.92 kg/m
Area
8.82 cm²
Ask about capacity, buckling or detailing for TFC 75x40x5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Tapered Channel section profile showing the dimension symbols used for TFC 75x40x5

Dimension symbols for Tapered Channel sections. Not to scale.

TFC 75x40x5 section properties to Continental Steel.

Geometry

Web thicknesstw5
Flange thicknesstf7
Root fillet radiusr8
Toe radiusr24

Mass and area

Mass per metremass6.92
Cross-sectional areaA8.82

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy75.9
Elastic section modulus about y-axisWel,y20.2
Radius of gyration about y-axisiy2.93

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz12.4
Elastic section modulus about z-axisWel,z4.54
Radius of gyration about z-axisiz1.19

Detailing dimensions

Centroid distance from back of leg (y)cy1.27

Common questions about TFC 75x40x5

TFC 75x40x5 has a mass of 6.92 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 83 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 20.2 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 75.9 cm⁴, and about the minor axis Iz is 12.4 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.93 cm about the major axis and iz is 1.19 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.19 cm a 0.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Tapered Channel sizes

TFC 50x25x5TFC 100x50x5TFC 125x65x6TFC 150x75x6.5TFC 150x75x9TFC 180x75x7TFC 180x90x7.5TFC 200x80x7.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Tapered Channel sizes
Tapered Flange Channels
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…