UB 406×140×39 - Section Properties

The UB 406×140×39 is a universal beam with a mass of 39 kg/m, an overall depth of 398 mm and width of 141.8 mm. It has a cross-sectional area of 49.7 cm², a second moment of area Iᵧ of 12500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 724 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
39 kg/m
Depth
398 mm
Width
141.8 mm
Area
49.7 cm²
Ask about capacity, buckling or detailing for UB 406×140×39.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 406×140×39

Dimension symbols for UB sections. Not to scale.

UB 406×140×39 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh398
Width of sectionb141.8
Web thicknesstw6.4
Flange thicknesstf8.6
Root fillet radiusr10.2
Depth between filletsd360.4

Mass and area

Mass per metremass39
Cross-sectional areaA49.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy12500
Elastic section modulus about y-axisWel,y629
Plastic section modulus about y-axisWpl,y724
Radius of gyration about y-axisiy15.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz410
Elastic section modulus about z-axisWel,z57.8
Plastic section modulus about z-axisWpl,z90.8
Radius of gyration about z-axisiz2.87

Torsion and warping

Torsion constant (St Venant)It10.7
Warping constantIw0.155

Classification and stability

Flange local-buckling ratiocf/tf6.69
Web local-buckling ratiocw/tw56.3
Buckling parameteru0.858
Torsional indexX47.4

Detailing dimensions

End clearanceC5
Notch dimension NN78
Notch dimension nn20

Surface area

Surface area per metreSA/m1.33
Surface area per tonneSA/t34.1m²/t

Is UB 406×140×39 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
78.0 / 257.0 kNm
Shear7%
39.0 / 566.0 kN
Deflection59%
13.2 / 22.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 406×140×39

UB 406×140×39 has a mass of 39 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 468 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 406×140×39 has a depth of 398 mm, a width of 141.8 mm, a web thickness of 6.4 mm, a flange thickness of 8.6 mm, with a cross-sectional area of 49.7 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 724 cm³, and the elastic modulus Wel,y is 629 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 257 kNm before any stability check.

The second moment of area about the major axis, Iy, is 12,500 cm⁴, and about the minor axis Iz is 410 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.69 for the flange and cw/tw = 56.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 15.9 cm about the major axis and iz is 2.87 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.87 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 10.7 cm⁴, and the warping constant Iw is 0.155 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 406×178×60UB 406×178×54UB 406×140×53UB 406×140×46UB 356×171×67UB 356×171×57UB 356×171×51UB 356×171×45

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 16X26

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…