CivilAxisCivilAxis
☕ Support🌐 Community

UB 356×171×57 - Section Properties

The UB 356×171×57 is a universal beam with a mass of 57 kg/m, an overall depth of 358 mm and width of 172.2 mm. It has a cross-sectional area of 72.6 cm², a second moment of area Iᵧ of 16000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1010 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
57 kg/m
Depth
358 mm
Width
172.2 mm
Area
72.6 cm²
Ask about capacity, buckling or detailing for UB 356×171×57.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 356×171×57

Dimension symbols for UB sections. Not to scale.

UB 356×171×57 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh358
Width of sectionb172.2
Web thicknesstw8.1
Flange thicknesstf13
Root fillet radiusr10.2
Depth between filletsd311.6

Mass and area

Mass per metremass57
Cross-sectional areaA72.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy16000
Elastic section modulus about y-axisWel,y896
Plastic section modulus about y-axisWpl,y1010
Radius of gyration about y-axisiy14.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1110
Elastic section modulus about z-axisWel,z129
Plastic section modulus about z-axisWpl,z199
Radius of gyration about z-axisiz3.91

Torsion and warping

Torsion constant (St Venant)It33.4
Warping constantIw0.33

Classification and stability

Flange local-buckling ratiocf/tf5.53
Web local-buckling ratiocw/tw38.5
Buckling parameteru0.882
Torsional indexX28.8

Detailing dimensions

End clearanceC6
Notch dimension NN94
Notch dimension nn24

Surface area

Surface area per metreSA/m1.37
Surface area per tonneSA/t24.1m²/t

Is UB 356×171×57 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending33%
119.4 / 358.6 kNm
Shear11%
68.3 / 646.3 kN
Deflection62%
12.1 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 356×171×57

UB 356×171×57 has a mass of 57 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 684 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 356×171×57 has a depth of 358 mm, a width of 172.2 mm, a web thickness of 8.1 mm, a flange thickness of 13 mm, with a cross-sectional area of 72.6 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,010 cm³, and the elastic modulus Wel,y is 896 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 359 kNm before any stability check.

The second moment of area about the major axis, Iy, is 16,000 cm⁴, and about the minor axis Iz is 1,110 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.53 for the flange and cw/tw = 38.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.9 cm about the major axis and iz is 3.91 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.91 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 33.4 cm⁴, and the warping constant Iw is 0.33 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 406×140×53UB 406×140×46UB 406×140×39UB 356×171×67UB 356×171×51UB 356×171×45UB 356×127×39UB 356×127×33

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 360vs W 14X38vs H-350x175x8x13

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…