UB 356×171×67 - Section Properties

The UB 356×171×67 is a universal beam with a mass of 67.1 kg/m, an overall depth of 363.4 mm and width of 173.2 mm. It has a cross-sectional area of 85.5 cm², a second moment of area Iᵧ of 19500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1210 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
67.1 kg/m
Depth
363.4 mm
Width
173.2 mm
Area
85.5 cm²
Ask about capacity, buckling or detailing for UB 356×171×67.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 356×171×67

Dimension symbols for UB sections. Not to scale.

UB 356×171×67 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh363.4
Width of sectionb173.2
Web thicknesstw9.1
Flange thicknesstf15.7
Root fillet radiusr10.2
Depth between filletsd311.6

Mass and area

Mass per metremass67.1
Cross-sectional areaA85.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy19500
Elastic section modulus about y-axisWel,y1070
Plastic section modulus about y-axisWpl,y1210
Radius of gyration about y-axisiy15.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1360
Elastic section modulus about z-axisWel,z157
Plastic section modulus about z-axisWpl,z243
Radius of gyration about z-axisiz3.99

Torsion and warping

Torsion constant (St Venant)It55.7
Warping constantIw0.412

Classification and stability

Flange local-buckling ratiocf/tf4.58
Web local-buckling ratiocw/tw34.2
Buckling parameteru0.886
Torsional indexX24.4

Detailing dimensions

End clearanceC7
Notch dimension NN94
Notch dimension nn26

Surface area

Surface area per metreSA/m1.38
Surface area per tonneSA/t20.6m²/t

Is UB 356×171×67 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending29%
126.6 / 429.6 kNm
Shear9%
67.5 / 732.7 kN
Deflection58%
12.1 / 20.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 356×171×67

UB 356×171×67 has a mass of 67.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 805 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 356×171×67 has a depth of 363.4 mm, a width of 173.2 mm, a web thickness of 9.1 mm, a flange thickness of 15.7 mm, with a cross-sectional area of 85.5 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,210 cm³, and the elastic modulus Wel,y is 1,070 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 430 kNm before any stability check.

The second moment of area about the major axis, Iy, is 19,500 cm⁴, and about the minor axis Iz is 1,360 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.58 for the flange and cw/tw = 34.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 15.1 cm about the major axis and iz is 3.99 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.99 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 55.7 cm⁴, and the warping constant Iw is 0.412 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 406×178×54UB 406×140×53UB 406×140×46UB 406×140×39UB 356×171×57UB 356×171×51UB 356×171×45UB 356×127×39

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 360vs H-350x175x9x15

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…