The UB 533×165×85 is a universal beam with a mass of 84.8 kg/m, an overall depth of 534.9 mm and width of 166.5 mm. It has a cross-sectional area of 108 cm², a second moment of area Iᵧ of 48500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2100 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
84.8 kg/m
Depth
534.9 mm
Width
166.5 mm
Area
108 cm²
Ask about capacity, buckling or detailing for UB 533×165×85.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 533×165×85

Dimension symbols for UB sections. Not to scale.

UB 533×165×85 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh534.9
Width of sectionb166.5
Web thicknesstw10.3
Flange thicknesstf16.5
Root fillet radiusr12.7
Depth between filletsd476.5

Mass and area

Mass per metremass84.8
Cross-sectional areaA108

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy48500
Elastic section modulus about y-axisWel,y1820
Plastic section modulus about y-axisWpl,y2100
Radius of gyration about y-axisiy21.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1270
Elastic section modulus about z-axisWel,z153
Plastic section modulus about z-axisWpl,z243
Radius of gyration about z-axisiz3.44

Torsion and warping

Torsion constant (St Venant)It73.8
Warping constantIw0.857

Classification and stability

Flange local-buckling ratiocf/tf3.96
Web local-buckling ratiocw/tw46.3
Buckling parameteru0.861
Torsional indexX35.5

Detailing dimensions

End clearanceC7
Notch dimension NN90
Notch dimension nn30

Surface area

Surface area per metreSA/m1.69
Surface area per tonneSA/t19.9m²/t

Is UB 533×165×85 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
227.4 / 745.5 kNm
Shear7%
86.6 / 1208.1 kN
Deflection59%
17.1 / 29.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 533×165×85

UB 533×165×85 has a mass of 84.8 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1018 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 533×165×85 has a depth of 534.9 mm, a width of 166.5 mm, a web thickness of 10.3 mm, a flange thickness of 16.5 mm, with a cross-sectional area of 108 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,100 cm³, and the elastic modulus Wel,y is 1,820 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 746 kNm before any stability check.

The second moment of area about the major axis, Iy, is 48,500 cm⁴, and about the minor axis Iz is 1,270 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.96 for the flange and cw/tw = 46.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 21.2 cm about the major axis and iz is 3.44 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.44 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 73.8 cm⁴, and the warping constant Iw is 0.857 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 533×210×109UB 533×210×101UB 533×210×92UB 533×210×82UB 533×165×75UB 533×165×66UB 457×191×161UB 457×191×133

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 21X57vs H-500x200x10x16-88.2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…