CivilAxisCivilAxis
☕ Support🌐 Community

UB 533×165×66 - Section Properties

The UB 533×165×66 is a universal beam with a mass of 65.7 kg/m, an overall depth of 524.7 mm and width of 165.1 mm. It has a cross-sectional area of 83.7 cm², a second moment of area Iᵧ of 35000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1560 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
65.7 kg/m
Depth
524.7 mm
Width
165.1 mm
Area
83.7 cm²
Ask about capacity, buckling or detailing for UB 533×165×66.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 533×165×66

Dimension symbols for UB sections. Not to scale.

UB 533×165×66 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh524.7
Width of sectionb165.1
Web thicknesstw8.9
Flange thicknesstf11.4
Root fillet radiusr12.7
Depth between filletsd476.5

Mass and area

Mass per metremass65.7
Cross-sectional areaA83.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy35000
Elastic section modulus about y-axisWel,y1340
Plastic section modulus about y-axisWpl,y1560
Radius of gyration about y-axisiy20.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz859
Elastic section modulus about z-axisWel,z104
Plastic section modulus about z-axisWpl,z166
Radius of gyration about z-axisiz3.2

Torsion and warping

Torsion constant (St Venant)It32
Warping constantIw0.566

Classification and stability

Flange local-buckling ratiocf/tf5.74
Web local-buckling ratiocw/tw53.5
Buckling parameteru0.847
Torsional indexX47

Detailing dimensions

End clearanceC6
Notch dimension NN90
Notch dimension nn26

Surface area

Surface area per metreSA/m1.67
Surface area per tonneSA/t25.4m²/t

Is UB 533×165×66 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
165.4 / 553.8 kNm
Shear6%
63.0 / 1024.1 kN
Deflection59%
17.2 / 29.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 533×165×66

UB 533×165×66 has a mass of 65.7 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 788 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 533×165×66 has a depth of 524.7 mm, a width of 165.1 mm, a web thickness of 8.9 mm, a flange thickness of 11.4 mm, with a cross-sectional area of 83.7 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,560 cm³, and the elastic modulus Wel,y is 1,340 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 554 kNm before any stability check.

The second moment of area about the major axis, Iy, is 35,000 cm⁴, and about the minor axis Iz is 859 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.74 for the flange and cw/tw = 53.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 20.5 cm about the major axis and iz is 3.2 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.2 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 32 cm⁴, and the warping constant Iw is 0.566 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 533×210×92UB 533×210×82UB 533×165×85UB 533×165×75UB 457×191×161UB 457×191×133UB 457×191×106UB 457×191×98

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 21X44

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…