CivilAxisCivilAxis
☕ Support🌐 Community

UB 457×191×106 - Section Properties

The UB 457×191×106 is a universal beam with a mass of 105.8 kg/m, an overall depth of 469.2 mm and width of 194 mm. It has a cross-sectional area of 135 cm², a second moment of area Iᵧ of 48900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2390 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
105.8 kg/m
Depth
469.2 mm
Width
194 mm
Area
135 cm²
Ask about capacity, buckling or detailing for UB 457×191×106.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 457×191×106

Dimension symbols for UB sections. Not to scale.

UB 457×191×106 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh469.2
Width of sectionb194
Web thicknesstw12.6
Flange thicknesstf20.6
Root fillet radiusr10.2
Depth between filletsd407.6

Mass and area

Mass per metremass105.8
Cross-sectional areaA135

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy48900
Elastic section modulus about y-axisWel,y2080
Plastic section modulus about y-axisWpl,y2390
Radius of gyration about y-axisiy19

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2510
Elastic section modulus about z-axisWel,z259
Plastic section modulus about z-axisWpl,z405
Radius of gyration about z-axisiz4.32

Torsion and warping

Torsion constant (St Venant)It146
Warping constantIw1.27

Classification and stability

Flange local-buckling ratiocf/tf3.91
Web local-buckling ratiocw/tw32.3
Buckling parameteru0.876
Torsional indexX24.4

Detailing dimensions

End clearanceC8
Notch dimension NN102
Notch dimension nn32

Surface area

Surface area per metreSA/m1.67
Surface area per tonneSA/t15.8m²/t

Is UB 457×191×106 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
253.8 / 848.5 kNm
Shear8%
106.9 / 1268.1 kN
Deflection59%
15.5 / 26.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 457×191×106

UB 457×191×106 has a mass of 105.8 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1270 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 457×191×106 has a depth of 469.2 mm, a width of 194 mm, a web thickness of 12.6 mm, a flange thickness of 20.6 mm, with a cross-sectional area of 135 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,390 cm³, and the elastic modulus Wel,y is 2,080 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 848 kNm before any stability check.

The second moment of area about the major axis, Iy, is 48,900 cm⁴, and about the minor axis Iz is 2,510 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.91 for the flange and cw/tw = 32.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 19 cm about the major axis and iz is 4.32 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.32 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 146 cm⁴, and the warping constant Iw is 1.27 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 533×165×75UB 533×165×66UB 457×191×161UB 457×191×133UB 457×191×98UB 457×191×89UB 457×191×82UB 457×191×74

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE V 450vs W 18X71vs H-450x200x14x19

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…