CivilAxisCivilAxis
☕ Support🌐 Community

UB 457×191×82 - Section Properties

The UB 457×191×82 is a universal beam with a mass of 82 kg/m, an overall depth of 460 mm and width of 191.3 mm. It has a cross-sectional area of 104 cm², a second moment of area Iᵧ of 37100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1830 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
82 kg/m
Depth
460 mm
Width
191.3 mm
Area
104 cm²
Ask about capacity, buckling or detailing for UB 457×191×82.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 457×191×82

Dimension symbols for UB sections. Not to scale.

UB 457×191×82 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh460
Width of sectionb191.3
Web thicknesstw9.9
Flange thicknesstf16
Root fillet radiusr10.2
Depth between filletsd407.6

Mass and area

Mass per metremass82
Cross-sectional areaA104

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy37100
Elastic section modulus about y-axisWel,y1610
Plastic section modulus about y-axisWpl,y1830
Radius of gyration about y-axisiy18.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1870
Elastic section modulus about z-axisWel,z196
Plastic section modulus about z-axisWpl,z304
Radius of gyration about z-axisiz4.23

Torsion and warping

Torsion constant (St Venant)It69.2
Warping constantIw0.922

Classification and stability

Flange local-buckling ratiocf/tf5.03
Web local-buckling ratiocw/tw41.2
Buckling parameteru0.879
Torsional indexX30.8

Detailing dimensions

End clearanceC7
Notch dimension NN102
Notch dimension nn28

Surface area

Surface area per metreSA/m1.65
Surface area per tonneSA/t20.1m²/t

Is UB 457×191×82 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
212.6 / 649.6 kNm
Shear10%
94.5 / 976.3 kN
Deflection61%
15.4 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 457×191×82

UB 457×191×82 has a mass of 82 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 984 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 457×191×82 has a depth of 460 mm, a width of 191.3 mm, a web thickness of 9.9 mm, a flange thickness of 16 mm, with a cross-sectional area of 104 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,830 cm³, and the elastic modulus Wel,y is 1,610 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 650 kNm before any stability check.

The second moment of area about the major axis, Iy, is 37,100 cm⁴, and about the minor axis Iz is 1,870 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.03 for the flange and cw/tw = 41.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.8 cm about the major axis and iz is 4.23 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.23 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 69.2 cm⁴, and the warping constant Iw is 0.922 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 457×191×133UB 457×191×106UB 457×191×98UB 457×191×89UB 457×191×74UB 457×191×67UB 457×152×82UB 457×152×74

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 18X55

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…