CivilAxisCivilAxis
☕ Support🌐 Community

UB 457×191×67 - Section Properties

The UB 457×191×67 is a universal beam with a mass of 67.1 kg/m, an overall depth of 453.4 mm and width of 189.9 mm. It has a cross-sectional area of 85.5 cm², a second moment of area Iᵧ of 29400 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1470 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
67.1 kg/m
Depth
453.4 mm
Width
189.9 mm
Area
85.5 cm²
Ask about capacity, buckling or detailing for UB 457×191×67.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 457×191×67

Dimension symbols for UB sections. Not to scale.

UB 457×191×67 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh453.4
Width of sectionb189.9
Web thicknesstw8.5
Flange thicknesstf12.7
Root fillet radiusr10.2
Depth between filletsd407.6

Mass and area

Mass per metremass67.1
Cross-sectional areaA85.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy29400
Elastic section modulus about y-axisWel,y1300
Plastic section modulus about y-axisWpl,y1470
Radius of gyration about y-axisiy18.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1450
Elastic section modulus about z-axisWel,z153
Plastic section modulus about z-axisWpl,z237
Radius of gyration about z-axisiz4.12

Torsion and warping

Torsion constant (St Venant)It37.1
Warping constantIw0.705

Classification and stability

Flange local-buckling ratiocf/tf6.34
Web local-buckling ratiocw/tw48
Buckling parameteru0.873
Torsional indexX37.8

Detailing dimensions

End clearanceC6
Notch dimension NN102
Notch dimension nn24

Surface area

Surface area per metreSA/m1.63
Surface area per tonneSA/t24.3m²/t

Is UB 457×191×67 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
167.1 / 521.9 kNm
Shear9%
74.3 / 839.0 kN
Deflection61%
15.2 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 457×191×67

UB 457×191×67 has a mass of 67.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 805 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 457×191×67 has a depth of 453.4 mm, a width of 189.9 mm, a web thickness of 8.5 mm, a flange thickness of 12.7 mm, with a cross-sectional area of 85.5 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,470 cm³, and the elastic modulus Wel,y is 1,300 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 522 kNm before any stability check.

The second moment of area about the major axis, Iy, is 29,400 cm⁴, and about the minor axis Iz is 1,450 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.34 for the flange and cw/tw = 48 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.5 cm about the major axis and iz is 4.12 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.12 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 37.1 cm⁴, and the warping constant Iw is 0.705 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 457×191×98UB 457×191×89UB 457×191×82UB 457×191×74UB 457×152×82UB 457×152×74UB 457×152×67UB 457×152×60

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE A 450vs W 18X46vs H-450x200x8x12-66.2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…