CivilAxisCivilAxis
☕ Support🌐 Community

UB 457×191×98 - Section Properties

The UB 457×191×98 is a universal beam with a mass of 98.3 kg/m, an overall depth of 467.2 mm and width of 192.8 mm. It has a cross-sectional area of 125 cm², a second moment of area Iᵧ of 45700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2230 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
98.3 kg/m
Depth
467.2 mm
Width
192.8 mm
Area
125 cm²
Ask about capacity, buckling or detailing for UB 457×191×98.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 457×191×98

Dimension symbols for UB sections. Not to scale.

UB 457×191×98 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh467.2
Width of sectionb192.8
Web thicknesstw11.4
Flange thicknesstf19.6
Root fillet radiusr10.2
Depth between filletsd407.6

Mass and area

Mass per metremass98.3
Cross-sectional areaA125

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy45700
Elastic section modulus about y-axisWel,y1960
Plastic section modulus about y-axisWpl,y2230
Radius of gyration about y-axisiy19.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2350
Elastic section modulus about z-axisWel,z243
Plastic section modulus about z-axisWpl,z379
Radius of gyration about z-axisiz4.33

Torsion and warping

Torsion constant (St Venant)It121
Warping constantIw1.18

Classification and stability

Flange local-buckling ratiocf/tf4.11
Web local-buckling ratiocw/tw35.8
Buckling parameteru0.881
Torsional indexX25.8

Detailing dimensions

End clearanceC8
Notch dimension NN102
Notch dimension nn30

Surface area

Surface area per metreSA/m1.67
Surface area per tonneSA/t17m²/t

Is UB 457×191×98 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
236.9 / 791.6 kNm
Shear9%
99.8 / 1140.7 kN
Deflection59%
15.5 / 26.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 457×191×98

UB 457×191×98 has a mass of 98.3 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1180 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 457×191×98 has a depth of 467.2 mm, a width of 192.8 mm, a web thickness of 11.4 mm, a flange thickness of 19.6 mm, with a cross-sectional area of 125 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,230 cm³, and the elastic modulus Wel,y is 1,960 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 792 kNm before any stability check.

The second moment of area about the major axis, Iy, is 45,700 cm⁴, and about the minor axis Iz is 2,350 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.11 for the flange and cw/tw = 35.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 19.1 cm about the major axis and iz is 4.33 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.33 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 121 cm⁴, and the warping constant Iw is 1.18 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 533×165×66UB 457×191×161UB 457×191×133UB 457×191×106UB 457×191×89UB 457×191×82UB 457×191×74UB 457×191×67

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 500vs IPE V 450vs W 18X65vs H-450x200x11x19

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…