IPE 500 is an IPE section from the European (Continental) range; UB 457×191×98 is the closest equivalent in the UK Blue Book (SCI P363). They are close to interchangeable in bending: 2190 cm³ against 2230 cm³ of plastic modulus, a difference of 1.8%. IPE 500 is the lighter of the two at 90.7 kg/m against 98.3 kg/m, a saving of 7.7% on steel weight. IPE 500 is deeper, 500 mm against 467.2 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyIPE 500
IPE
UB 457×191×98
UB
Difference
Mass90.7 kg/m98.3 kg/m-7.7%
Depth500 mm467.2 mm+7.0%
Width200 mm192.8 mm+3.7%
Web thickness10.2 mm11.4 mm-10.5%
Flange thickness16 mm19.6 mm-18.4%
Area116 cm²125 cm²-7.2%
Second moment, major (Iy)48,200 cm⁴45,700 cm⁴+5.5%
Plastic modulus, major (Wpl,y)2,190 cm³2,230 cm³-1.8%
Elastic modulus, major (Wel,y)1,930 cm³1,960 cm³-1.5%
Second moment, minor (Iz)2,140 cm⁴2,350 cm⁴-8.9%
Plastic modulus, minor (Wpl,z)336 cm³379 cm³-11.3%
Radius of gyration, minor (iz)4.31 cm4.33 cm-0.5%
Torsion constant (It)89.1 cm⁴121 cm⁴-26.4%

IPE 500 to EN 10365 · Continental Steel; UB 457×191×98 to BS EN 10365:2017. Difference is expressed relative to UB 457×191×98.

How to choose between them

On stiffness, IPE 500 has the larger second moment of area: 48,200 cm⁴ against 45,700 cm⁴, a difference of 5.5%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, IPE 500 is the more efficient section: 24.1 against 22.7 cm³ per kg/m, 6.4% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: UB 457×191×98 has 379 cm³ of minor-axis plastic modulus against 336 cm³, 11.3% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. IPE sections are specified to EN 10365 · Continental Steel and UB to BS EN 10365:2017; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 7.7% weight.

In short, UB 457×191×98 is the stronger section and IPE 500 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. IPE 500 has a plastic modulus of 2190 cm³ and UB 457×191×98 has 2230 cm³, a difference of only 1.8% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

IPE 500 at 90.7 kg/m, against 98.3 kg/m for the other - a saving of 7.7%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: UB 457×191×98 gives 2230 cm³ of plastic modulus and 45,700 cm⁴ of inertia against 2190 cm³ and 48,200 cm⁴. But they are from different catalogues (EN 10365 · Continental Steel and BS EN 10365:2017), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.