CivilAxisCivilAxis
☕ Support🌐 Community

UB 533×312×151 - Section Properties

The UB 533×312×151 is a universal beam with a mass of 150.6 kg/m, an overall depth of 542.5 mm and width of 312 mm. It has a cross-sectional area of 192 cm², a second moment of area Iᵧ of 101000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4150 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
150.6 kg/m
Depth
542.5 mm
Width
312 mm
Area
192 cm²
Ask about capacity, buckling or detailing for UB 533×312×151.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 533×312×151

Dimension symbols for UB sections. Not to scale.

UB 533×312×151 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh542.5
Width of sectionb312
Web thicknesstw12.7
Flange thicknesstf20.3
Root fillet radiusr12.7
Depth between filletsd476.5

Mass and area

Mass per metremass150.6
Cross-sectional areaA192

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy101000
Elastic section modulus about y-axisWel,y3710
Plastic section modulus about y-axisWpl,y4150
Radius of gyration about y-axisiy22.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz10300
Elastic section modulus about z-axisWel,z659
Plastic section modulus about z-axisWpl,z1010
Radius of gyration about z-axisiz7.32

Torsion and warping

Torsion constant (St Venant)It216
Warping constantIw7.01

Classification and stability

Flange local-buckling ratiocf/tf6.75
Web local-buckling ratiocw/tw37.5
Buckling parameteru0.885
Torsional indexX27.8

Detailing dimensions

End clearanceC8
Notch dimension NN160
Notch dimension nn34

Surface area

Surface area per metreSA/m2.29
Surface area per tonneSA/t15.2m²/t

Is UB 533×312×151 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
453.8 / 1473.3 kNm
Shear11%
165.0 / 1497.5 kN
Deflection59%
18.0 / 30.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 533×312×151

UB 533×312×151 has a mass of 150.6 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1807 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 533×312×151 has a depth of 542.5 mm, a width of 312 mm, a web thickness of 12.7 mm, a flange thickness of 20.3 mm, with a cross-sectional area of 192 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,150 cm³, and the elastic modulus Wel,y is 3,710 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1473 kNm before any stability check.

The second moment of area about the major axis, Iy, is 101,000 cm⁴, and about the minor axis Iz is 10,300 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.75 for the flange and cw/tw = 37.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 22.9 cm about the major axis and iz is 7.32 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.32 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 216 cm⁴, and the warping constant Iw is 7.01 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 610×178×82UB 533×312×273UB 533×312×219UB 533×312×182UB 533×210×138UB 533×210×122UB 533×210×109UB 533×210×101

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE V 550vs W 21X101

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…