CivilAxisCivilAxis
☕ Support🌐 Community

UB 533×210×122 - Section Properties

The UB 533×210×122 is a universal beam with a mass of 122 kg/m, an overall depth of 544.5 mm and width of 211.9 mm. It has a cross-sectional area of 155 cm², a second moment of area Iᵧ of 76000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3200 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
122 kg/m
Depth
544.5 mm
Width
211.9 mm
Area
155 cm²
Ask about capacity, buckling or detailing for UB 533×210×122.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 533×210×122

Dimension symbols for UB sections. Not to scale.

UB 533×210×122 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh544.5
Width of sectionb211.9
Web thicknesstw12.7
Flange thicknesstf21.3
Root fillet radiusr12.7
Depth between filletsd476.5

Mass and area

Mass per metremass122
Cross-sectional areaA155

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy76000
Elastic section modulus about y-axisWel,y2790
Plastic section modulus about y-axisWpl,y3200
Radius of gyration about y-axisiy22.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3390
Elastic section modulus about z-axisWel,z320
Plastic section modulus about z-axisWpl,z500
Radius of gyration about z-axisiz4.67

Torsion and warping

Torsion constant (St Venant)It178
Warping constantIw2.32

Classification and stability

Flange local-buckling ratiocf/tf4.08
Web local-buckling ratiocw/tw37.5
Buckling parameteru0.878
Torsional indexX27.6

Detailing dimensions

End clearanceC8
Notch dimension NN110
Notch dimension nn34

Surface area

Surface area per metreSA/m1.89
Surface area per tonneSA/t15.5m²/t

Is UB 533×210×122 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
340.3 / 1136.0 kNm
Shear8%
123.8 / 1493.0 kN
Deflection59%
17.9 / 30.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 533×210×122

UB 533×210×122 has a mass of 122 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1464 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 533×210×122 has a depth of 544.5 mm, a width of 211.9 mm, a web thickness of 12.7 mm, a flange thickness of 21.3 mm, with a cross-sectional area of 155 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,200 cm³, and the elastic modulus Wel,y is 2,790 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1136 kNm before any stability check.

The second moment of area about the major axis, Iy, is 76,000 cm⁴, and about the minor axis Iz is 3,390 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.08 for the flange and cw/tw = 37.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 22.1 cm about the major axis and iz is 4.67 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.67 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 178 cm⁴, and the warping constant Iw is 2.32 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 533×312×219UB 533×312×182UB 533×312×151UB 533×210×138UB 533×210×109UB 533×210×101UB 533×210×92UB 533×210×82

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 550vs HE 550 AAvs W 21X83vs S 20X96

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…