CivilAxisCivilAxis
☕ Support🌐 Community

UBP 305×305×186 - Section Properties

The UBP 305×305×186 is a universal bearing pile with a mass of 186 kg/m, an overall depth of 328.3 mm and width of 320.9 mm. It has a cross-sectional area of 237 cm², a second moment of area Iᵧ of 42600 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3000 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
186 kg/m
Depth
328.3 mm
Width
320.9 mm
Area
237 cm²
Ask about capacity, buckling or detailing for UBP 305×305×186.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UBP section profile showing the dimension symbols used for UBP 305×305×186

Dimension symbols for UBP sections. Not to scale.

UBP 305×305×186 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh328.3
Width of sectionb320.9
Web thicknesstw25.5
Flange thicknesstf25.6
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass186
Cross-sectional areaA237

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy42600
Elastic section modulus about y-axisWel,y2600
Plastic section modulus about y-axisWpl,y3000
Radius of gyration about y-axisiy13.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz14100
Elastic section modulus about z-axisWel,z881
Plastic section modulus about z-axisWpl,z1370
Radius of gyration about z-axisiz7.73

Torsion and warping

Torsion constant (St Venant)It560
Warping constantIw3.24

Classification and stability

Flange local-buckling ratiocf/tf5.18
Web local-buckling ratiocw/tw9.67
Buckling parameteru0.827
Torsional indexX11.1

Detailing dimensions

End clearanceC15
Notch dimension NN158
Notch dimension nn42

Surface area

Surface area per metreSA/m1.86
Surface area per tonneSA/t10m²/t

Is UBP 305×305×186 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
332.7 / 1065.0 kNm
Shear11%
204.8 / 1783.3 kN
Deflection60%
10.9 / 18.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UBP 305×305×186

UBP 305×305×186 has a mass of 186 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2232 kg, which is the figure to use for a steel take-off or when checking a lift.

UBP 305×305×186 has a depth of 328.3 mm, a width of 320.9 mm, a web thickness of 25.5 mm, a flange thickness of 25.6 mm, with a cross-sectional area of 237 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,000 cm³, and the elastic modulus Wel,y is 2,600 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1065 kNm before any stability check.

The second moment of area about the major axis, Iy, is 42,600 cm⁴, and about the minor axis Iz is 14,100 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.18 for the flange and cw/tw = 9.67 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13.4 cm about the major axis and iz is 7.73 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.73 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 560 cm⁴, and the warping constant Iw is 3.24 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UBP sizes

UBP 356×368×152UBP 356×368×133UBP 356×368×109UBP 305×305×223UBP 305×305×149UBP 305×305×126UBP 305×305×110UBP 305×305×95

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UBP sizes
Universal Bearing Piles (UBP)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…