CivilAxisCivilAxis
☕ Support🌐 Community

UBP 305×305×110 - Section Properties

The UBP 305×305×110 is a universal bearing pile with a mass of 110 kg/m, an overall depth of 307.9 mm and width of 310.7 mm. It has a cross-sectional area of 140 cm², a second moment of area Iᵧ of 23600 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1720 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
110 kg/m
Depth
307.9 mm
Width
310.7 mm
Area
140 cm²
Ask about capacity, buckling or detailing for UBP 305×305×110.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UBP section profile showing the dimension symbols used for UBP 305×305×110

Dimension symbols for UBP sections. Not to scale.

UBP 305×305×110 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh307.9
Width of sectionb310.7
Web thicknesstw15.3
Flange thicknesstf15.4
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass110
Cross-sectional areaA140

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy23600
Elastic section modulus about y-axisWel,y1530
Plastic section modulus about y-axisWpl,y1720
Radius of gyration about y-axisiy13

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7710
Elastic section modulus about z-axisWel,z496
Plastic section modulus about z-axisWpl,z762
Radius of gyration about z-axisiz7.42

Torsion and warping

Torsion constant (St Venant)It122
Warping constantIw1.65

Classification and stability

Flange local-buckling ratiocf/tf8.6
Web local-buckling ratiocw/tw16.1
Buckling parameteru0.83
Torsional indexX17.7

Detailing dimensions

End clearanceC10
Notch dimension NN158
Notch dimension nn32

Surface area

Surface area per metreSA/m1.8
Surface area per tonneSA/t16.4m²/t

Is UBP 305×305×110 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending36%
195.8 / 543.1 kNm
Shear12%
130.5 / 1052.3 kN
Deflection59%
9.9 / 16.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UBP 305×305×110

UBP 305×305×110 has a mass of 110 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1320 kg, which is the figure to use for a steel take-off or when checking a lift.

UBP 305×305×110 has a depth of 307.9 mm, a width of 310.7 mm, a web thickness of 15.3 mm, a flange thickness of 15.4 mm, with a cross-sectional area of 140 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,720 cm³, and the elastic modulus Wel,y is 1,530 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 611 kNm before any stability check.

The second moment of area about the major axis, Iy, is 23,600 cm⁴, and about the minor axis Iz is 7,710 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.6 for the flange and cw/tw = 16.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13 cm about the major axis and iz is 7.42 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.42 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 122 cm⁴, and the warping constant Iw is 1.65 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UBP sizes

UBP 305×305×223UBP 305×305×186UBP 305×305×149UBP 305×305×126UBP 305×305×95UBP 305×305×88UBP 305×305×79UBP 254×254×85

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UBP sizes
Universal Bearing Piles (UBP)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…