CivilAxisCivilAxis
☕ Support🌐 Community

UBP 305×305×88 - Section Properties

The UBP 305×305×88 is a universal bearing pile with a mass of 88 kg/m, an overall depth of 301.7 mm and width of 307.8 mm. It has a cross-sectional area of 112 cm², a second moment of area Iᵧ of 18400 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1360 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
88 kg/m
Depth
301.7 mm
Width
307.8 mm
Area
112 cm²
Ask about capacity, buckling or detailing for UBP 305×305×88.
🔍 Open the full Steel Catalogue →📖 Design theory📐 Worked example
or pick a unit on any row
UBP section profile showing the dimension symbols used for UBP 305×305×88

Dimension symbols for UBP sections. Not to scale.

UBP 305×305×88 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh301.7
Width of sectionb307.8
Web thicknesstw12.4
Flange thicknesstf12.3
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass88
Cross-sectional areaA112

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy18400
Elastic section modulus about y-axisWel,y1220
Plastic section modulus about y-axisWpl,y1360
Radius of gyration about y-axisiy12.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz5980
Elastic section modulus about z-axisWel,z389
Plastic section modulus about z-axisWpl,z595
Radius of gyration about z-axisiz7.31

Torsion and warping

Torsion constant (St Venant)It64.2
Warping constantIw1.25

Classification and stability

Flange local-buckling ratiocf/tf10.77
Web local-buckling ratiocw/tw19.9
Buckling parameteru0.831
Torsional indexX21.6

Detailing dimensions

End clearanceC8
Notch dimension NN158
Notch dimension nn28

Surface area

Surface area per metreSA/m1.78
Surface area per tonneSA/t20.3m²/t

Is UBP 305×305×88 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

✅Passes - 60% utilised, deflection governs
Bending36%
155.3 / 433.1 kNm
Shear12%
103.5 / 851.5 kN
Deflection60%
10.0 / 16.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UBP 305×305×88

UBP 305×305×88 has a mass of 88 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1056 kg, which is the figure to use for a steel take-off or when checking a lift.

UBP 305×305×88 has a depth of 301.7 mm, a width of 307.8 mm, a web thickness of 12.4 mm, a flange thickness of 12.3 mm, with a cross-sectional area of 112 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,360 cm³, and the elastic modulus Wel,y is 1,220 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 483 kNm before any stability check.

The second moment of area about the major axis, Iy, is 18,400 cm⁴, and about the minor axis Iz is 5,980 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 10.77 for the flange and cw/tw = 19.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.8 cm about the major axis and iz is 7.31 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.31 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 64.2 cm⁴, and the warping constant Iw is 1.25 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UBP sizes

UBP 305×305×149UBP 305×305×126UBP 305×305×110UBP 305×305×95UBP 305×305×79UBP 254×254×85UBP 254×254×71UBP 254×254×63

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE) →📘 Section modulus explained: elastic (Wel) vs plastic (Wpl) →📘 IPE vs HE (HEA/HEB): choosing a European steel beam →
All UBP sizes →