CivilAxisCivilAxis
☕ Support🌐 Community

UBP 254×254×63 - Section Properties

The UBP 254×254×63 is a universal bearing pile with a mass of 63 kg/m, an overall depth of 247.1 mm and width of 256.6 mm. It has a cross-sectional area of 80.2 cm², a second moment of area Iᵧ of 8860 cm⁴, a plastic modulus Wₚₗ,ᵧ of 799 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
63 kg/m
Depth
247.1 mm
Width
256.6 mm
Area
80.2 cm²
Ask about capacity, buckling or detailing for UBP 254×254×63.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UBP section profile showing the dimension symbols used for UBP 254×254×63

Dimension symbols for UBP sections. Not to scale.

UBP 254×254×63 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh247.1
Width of sectionb256.6
Web thicknesstw10.6
Flange thicknesstf10.7
Root fillet radiusr12.7
Depth between filletsd200.3

Mass and area

Mass per metremass63
Cross-sectional areaA80.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy8860
Elastic section modulus about y-axisWel,y717
Plastic section modulus about y-axisWpl,y799
Radius of gyration about y-axisiy10.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3020
Elastic section modulus about z-axisWel,z235
Plastic section modulus about z-axisWpl,z360
Radius of gyration about z-axisiz6.13

Torsion and warping

Torsion constant (St Venant)It34.3
Warping constantIw0.421

Classification and stability

Flange local-buckling ratiocf/tf10.31
Web local-buckling ratiocw/tw18.9
Buckling parameteru0.828
Torsional indexX20.4

Detailing dimensions

End clearanceC7
Notch dimension NN134
Notch dimension nn24

Surface area

Surface area per metreSA/m1.48
Surface area per tonneSA/t23.5m²/t

Is UBP 254×254×63 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending35%
89.1 / 254.5 kNm
Shear12%
71.3 / 597.2 kN
Deflection60%
8.3 / 13.9 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UBP 254×254×63

UBP 254×254×63 has a mass of 63 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 756 kg, which is the figure to use for a steel take-off or when checking a lift.

UBP 254×254×63 has a depth of 247.1 mm, a width of 256.6 mm, a web thickness of 10.6 mm, a flange thickness of 10.7 mm, with a cross-sectional area of 80.2 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 799 cm³, and the elastic modulus Wel,y is 717 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 284 kNm before any stability check.

The second moment of area about the major axis, Iy, is 8,860 cm⁴, and about the minor axis Iz is 3,020 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 10.31 for the flange and cw/tw = 18.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.5 cm about the major axis and iz is 6.13 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.13 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 34.3 cm⁴, and the warping constant Iw is 0.421 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UBP sizes

UBP 305×305×110UBP 305×305×95UBP 305×305×88UBP 305×305×79UBP 254×254×85UBP 254×254×71UBP 203×203×54UBP 203×203×45

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UBP sizes
Universal Bearing Piles (UBP)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…