CivilAxisCivilAxis
☕ Support🌐 Community

UBP 203×203×45 - Section Properties

The UBP 203×203×45 is a universal bearing pile with a mass of 44.9 kg/m, an overall depth of 200.2 mm and width of 205.9 mm. It has a cross-sectional area of 57.2 cm², a second moment of area Iᵧ of 4100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 459 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
44.9 kg/m
Depth
200.2 mm
Width
205.9 mm
Area
57.2 cm²
Ask about capacity, buckling or detailing for UBP 203×203×45.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UBP section profile showing the dimension symbols used for UBP 203×203×45

Dimension symbols for UBP sections. Not to scale.

UBP 203×203×45 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh200.2
Width of sectionb205.9
Web thicknesstw9.5
Flange thicknesstf9.5
Root fillet radiusr10.2
Depth between filletsd160.8

Mass and area

Mass per metremass44.9
Cross-sectional areaA57.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4100
Elastic section modulus about y-axisWel,y410
Plastic section modulus about y-axisWpl,y459
Radius of gyration about y-axisiy8.46

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1380
Elastic section modulus about z-axisWel,z134
Plastic section modulus about z-axisWpl,z206
Radius of gyration about z-axisiz4.92

Torsion and warping

Torsion constant (St Venant)It19.2
Warping constantIw0.126

Classification and stability

Flange local-buckling ratiocf/tf9.26
Web local-buckling ratiocw/tw16.9
Buckling parameteru0.827
Torsional indexX18.6

Detailing dimensions

End clearanceC7
Notch dimension NN110
Notch dimension nn20

Surface area

Surface area per metreSA/m1.19
Surface area per tonneSA/t26.4m²/t

Is UBP 203×203×45 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending35%
51.0 / 145.6 kNm
Shear12%
51.0 / 428.8 kN
Deflection59%
6.6 / 11.1 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UBP 203×203×45

UBP 203×203×45 has a mass of 44.9 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 539 kg, which is the figure to use for a steel take-off or when checking a lift.

UBP 203×203×45 has a depth of 200.2 mm, a width of 205.9 mm, a web thickness of 9.5 mm, a flange thickness of 9.5 mm, with a cross-sectional area of 57.2 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 459 cm³, and the elastic modulus Wel,y is 410 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 163 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,100 cm⁴, and about the minor axis Iz is 1,380 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 9.26 for the flange and cw/tw = 16.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.46 cm about the major axis and iz is 4.92 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.92 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 19.2 cm⁴, and the warping constant Iw is 0.126 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UBP sizes

UBP 305×305×110UBP 305×305×95UBP 305×305×88UBP 305×305×79UBP 254×254×85UBP 254×254×71UBP 254×254×63UBP 203×203×54

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UBP sizes
Universal Bearing Piles (UBP)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.