CivilAxisCivilAxis
☕ Support🌐 Community

UJ 254×114×37 - Section Properties

The UJ 254×114×37 is a universal joist with a mass of 37.2 kg/m, an overall depth of 254 mm and width of 114.3 mm. It has a cross-sectional area of 47.3 cm², a second moment of area Iᵧ of 5080 cm⁴, a plastic modulus Wₚₗ,ᵧ of 459 cm³, tabulated by CivilAxis from BS 4-1:2005 (SCI P363 Blue Book).

Mass
37.2 kg/m
Depth
254 mm
Width
114.3 mm
Area
47.3 cm²
Ask about capacity, buckling or detailing for UJ 254×114×37.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UJ section profile showing the dimension symbols used for UJ 254×114×37

Dimension symbols for UJ sections. Not to scale.

UJ 254×114×37 section properties to BS 4-1:2005.

Geometry

Depth of sectionh254
Width of sectionb114.3
Web thicknesstw7.6
Flange thicknesstf12.8
Root fillet radiusr12.4
Toe radiusr26.1
Depth between filletsd199.3

Mass and area

Mass per metremass37.2
Cross-sectional areaA47.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5080
Elastic section modulus about y-axisWel,y400
Plastic section modulus about y-axisWpl,y459
Radius of gyration about y-axisiy10.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz269
Elastic section modulus about z-axisWel,z47.1
Plastic section modulus about z-axisWpl,z79.1
Radius of gyration about z-axisiz2.39

Torsion and warping

Torsion constant (St Venant)It25.2
Warping constantIw0.0392

Classification and stability

Flange local-buckling ratiocf/tf3.2
Web local-buckling ratiocw/tw26.2
Buckling parameteru0.884
Torsional indexX18.7

Detailing dimensions

End clearanceC6
Notch dimension NN60
Notch dimension nn28

Surface area

Surface area per metreSA/m0.899
Surface area per tonneSA/t24.2m²/t

Is UJ 254×114×37 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending32%
51.6 / 162.9 kNm
Shear9%
41.3 / 454.7 kN
Deflection60%
8.4 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UJ 254×114×37

UJ 254×114×37 has a mass of 37.2 kg/m, tabulated to BS 4-1:2005. A 12 m length therefore weighs about 446 kg, which is the figure to use for a steel take-off or when checking a lift.

UJ 254×114×37 has a depth of 254 mm, a width of 114.3 mm, a web thickness of 7.6 mm, a flange thickness of 12.8 mm, with a cross-sectional area of 47.3 cm². These are the nominal dimensions from BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 459 cm³, and the elastic modulus Wel,y is 400 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 163 kNm before any stability check.

The second moment of area about the major axis, Iy, is 5,080 cm⁴, and about the minor axis Iz is 269 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.2 for the flange and cw/tw = 26.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.4 cm about the major axis and iz is 2.39 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.39 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 25.2 cm⁴, and the warping constant Iw is 0.0392 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UJ sizes

UJ 254×203×82UJ 203×152×52UJ 152×127×37UJ 127×114×29UJ 127×114×27UJ 127×76×16UJ 114×114×27UJ 102×102×23

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UJ sizes
Universal Joists (UJ)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…