CivilAxisCivilAxis
☕ Support🌐 Community

UJ 254×203×82 - Section Properties

The UJ 254×203×82 is a universal joist with a mass of 82 kg/m, an overall depth of 254 mm and width of 203.2 mm. It has a cross-sectional area of 105 cm², a second moment of area Iᵧ of 12000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1080 cm³, tabulated by CivilAxis from BS 4-1:2005 (SCI P363 Blue Book).

Mass
82 kg/m
Depth
254 mm
Width
203.2 mm
Area
105 cm²
Ask about capacity, buckling or detailing for UJ 254×203×82.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UJ section profile showing the dimension symbols used for UJ 254×203×82

Dimension symbols for UJ sections. Not to scale.

UJ 254×203×82 section properties to BS 4-1:2005.

Geometry

Depth of sectionh254
Width of sectionb203.2
Web thicknesstw10.2
Flange thicknesstf19.9
Root fillet radiusr19.6
Toe radiusr29.7
Depth between filletsd166.6

Mass and area

Mass per metremass82
Cross-sectional areaA105

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy12000
Elastic section modulus about y-axisWel,y947
Plastic section modulus about y-axisWpl,y1080
Radius of gyration about y-axisiy10.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2280
Elastic section modulus about z-axisWel,z224
Plastic section modulus about z-axisWpl,z371
Radius of gyration about z-axisiz4.67

Torsion and warping

Torsion constant (St Venant)It152
Warping constantIw0.312

Classification and stability

Flange local-buckling ratiocf/tf3.86
Web local-buckling ratiocw/tw16.3
Buckling parameteru0.888
Torsional indexX11

Detailing dimensions

End clearanceC7
Notch dimension NN104
Notch dimension nn44

Surface area

Surface area per metreSA/m1.21
Surface area per tonneSA/t14.8m²/t

Is UJ 254×203×82 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending32%
121.9 / 383.4 kNm
Shear14%
97.5 / 696.0 kN
Deflection60%
8.4 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UJ 254×203×82

UJ 254×203×82 has a mass of 82 kg/m, tabulated to BS 4-1:2005. A 12 m length therefore weighs about 984 kg, which is the figure to use for a steel take-off or when checking a lift.

UJ 254×203×82 has a depth of 254 mm, a width of 203.2 mm, a web thickness of 10.2 mm, a flange thickness of 19.9 mm, with a cross-sectional area of 105 cm². These are the nominal dimensions from BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,080 cm³, and the elastic modulus Wel,y is 947 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 383 kNm before any stability check.

The second moment of area about the major axis, Iy, is 12,000 cm⁴, and about the minor axis Iz is 2,280 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.86 for the flange and cw/tw = 16.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.7 cm about the major axis and iz is 4.67 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.67 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 152 cm⁴, and the warping constant Iw is 0.312 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UJ sizes

UJ 254×114×37UJ 203×152×52UJ 152×127×37UJ 127×114×29UJ 127×114×27UJ 127×76×16UJ 114×114×27UJ 102×102×23

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UJ sizes
Universal Joists (UJ)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…