CivilAxisCivilAxis
☕ Support🌐 Community

Z10019 - Section Properties

The Z10019 is a cold-formed Z-purlin with a mass of 3.29 kg/m, an overall depth of 102 mm and width of 53 mm and a wall thickness of 1.9 mm. It has a cross-sectional area of 4.09 cm², a second moment of area Iᵧ of 2.94 cm⁴, an elastic modulus Wₑₗ,ᵧ of 28.1 cm³, tabulated by CivilAxis from Continental Steel.

Mass
3.29 kg/m
Depth
102 mm
Width
53 mm
Wall thickness
1.9 mm
Area
4.09 cm²
Ask about capacity, buckling or detailing for Z10019.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Z10019 section properties to Continental Steel.

Geometry

Depth of sectionh102
Width of sectionb53
Wall thicknesst1.9

Mass and area

Mass per metremass3.29
Cross-sectional areaA4.09

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2.94
Elastic section modulus about y-axisWel,y28.1
Radius of gyration about y-axisiy25

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz14.2
Elastic section modulus about z-axisWel,z67.3
Radius of gyration about z-axisiz31.4

Principal axes

Area moment of inertia about u-u (major principal) axisIu84
Area moment of inertia about v-v (minor principal) axisIv8.29

Common questions about Z10019

Z10019 has a mass of 3.29 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 39 kg, which is the figure to use for a steel take-off or when checking a lift.

Z10019 has a depth of 102 mm, a width of 53 mm, a wall thickness of 1.9 mm, with a cross-sectional area of 4.09 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The elastic section modulus about the major axis, Wel,y, is 28.1 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 2.94 cm⁴, and about the minor axis Iz is 14.2 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 25 cm about the major axis and iz is 31.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 31.4 cm a 3.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Z-Purlin sizes

Z10010Z10012Z10015Z15012Z15015Z15019Z15024Z20015

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)