CivilAxisCivilAxis
☕ Support🌐 Community

Z15019 - Section Properties

The Z15019 is a cold-formed Z-purlin with a mass of 4.51 kg/m, an overall depth of 152 mm and width of 65 mm and a wall thickness of 1.9 mm. It has a cross-sectional area of 5.61 cm², a second moment of area Iᵧ of 5.02 cm⁴, an elastic modulus Wₑₗ,ᵧ of 22.1 cm³, tabulated by CivilAxis from Continental Steel.

Mass
4.51 kg/m
Depth
152 mm
Width
65 mm
Wall thickness
1.9 mm
Area
5.61 cm²
Ask about capacity, buckling or detailing for Z15019.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Z15019 section properties to Continental Steel.

Geometry

Depth of sectionh152
Width of sectionb65
Wall thicknesst1.9

Mass and area

Mass per metremass4.51
Cross-sectional areaA5.61

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5.02
Elastic section modulus about y-axisWel,y22.1
Radius of gyration about y-axisiy48.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz18.1
Elastic section modulus about z-axisWel,z201
Radius of gyration about z-axisiz74.4

Principal axes

Area moment of inertia about u-u (major principal) axisIu232
Area moment of inertia about v-v (minor principal) axisIv1.84

Common questions about Z15019

Z15019 has a mass of 4.51 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 54 kg, which is the figure to use for a steel take-off or when checking a lift.

Z15019 has a depth of 152 mm, a width of 65 mm, a wall thickness of 1.9 mm, with a cross-sectional area of 5.61 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The elastic section modulus about the major axis, Wel,y, is 22.1 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 5.02 cm⁴, and about the minor axis Iz is 18.1 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 48.7 cm about the major axis and iz is 74.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 74.4 cm a 7.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Z-Purlin sizes

Z10015Z10019Z15012Z15015Z15024Z20015Z20019Z20024

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Z-Purlin sizes
Z-Purlins (cold-formed)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.