W 12X79 is an W section from the American AISC Shapes Database; H-300x300x13x20 is the closest equivalent in the European (Continental) range. H-300x300x13x20 carries more bending: 2031 cm³ of plastic modulus against 1950.1 cm³, 4.0% more. W 12X79 is the lighter of the two at 117.6 kg/m against 125 kg/m, a saving of 5.9% on steel weight. Both are about 313 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 12X79
W
H-300x300x13x20
MB & MC
Difference
Mass117.6 kg/m125 kg/m-5.9%
Depth315 mm310 mm+1.6%
Width307.3 mm303 mm+1.4%
Web thickness11.9 mm13 mm-8.5%
Flange thickness18.7 mm20 mm-6.5%
Area149.7 cm²159 cm²-5.8%
Second moment, major (Iy)27,555 cm⁴28,130 cm⁴-2.0%
Plastic modulus, major (Wpl,y)1,950.1 cm³2,031 cm³-4.0%
Elastic modulus, major (Wel,y)1,753.4 cm³1,815 cm³-3.4%
Second moment, minor (Iz)8,991 cm⁴9,282 cm⁴-3.1%
Plastic modulus, minor (Wpl,z)889.82 cm³932 cm³-4.5%
Radius of gyration, minor (iz)7.75 cm7.64 cm+1.4%
Torsion constant (It)159.8 cm⁴200 cm⁴-20.1%

W 12X79 to AISC Shapes Database v16.0; H-300x300x13x20 to Continental Steel. Difference is expressed relative to H-300x300x13x20.

How to choose between them

On stiffness, H-300x300x13x20 has the larger second moment of area: 28,130 cm⁴ against 27,555 cm⁴, a difference of 2.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, W 12X79 is the more efficient section: 16.6 against 16.2 cm³ per kg/m, 2.1% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and MB & MC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 5.9% weight.

In short, H-300x300x13x20 is the stronger section and W 12X79 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

H-300x300x13x20 is the stronger of the two in bending, with a plastic modulus of 2031 cm³ against 1950.1 cm³ - 4.0% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

W 12X79 at 117.6 kg/m, against 125 kg/m for the other - a saving of 5.9%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-300x300x13x20 gives 2031 cm³ of plastic modulus and 28,130 cm⁴ of inertia against 1950.1 cm³ and 27,555 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

H-300x300x13x20, with a second moment of area of 28,130 cm⁴ against 27,555 cm⁴ (2.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.