W 44X290 is an W section from the American AISC Shapes Database; UB 1016×305×487 is the closest equivalent in the UK Blue Book (SCI P363). They are close to interchangeable in bending: 23105.8 cm³ against 23200 cm³ of plastic modulus, a difference of 0.4%. W 44X290 is the lighter of the two at 431.6 kg/m against 486.7 kg/m, a saving of 11.3% on steel weight. W 44X290 is deeper, 1107.4 mm against 1036.3 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 44X290
W
UB 1016×305×487
UB
Difference
Mass431.6 kg/m486.7 kg/m-11.3%
Depth1107.4 mm1036.3 mm+6.9%
Width401.3 mm308.5 mm+30.1%
Web thickness22 mm30 mm-26.7%
Flange thickness40.1 mm54.1 mm-25.9%
Area551 cm²620 cm²-11.1%
Second moment, major (Iy)1,123,825 cm⁴1,022,000 cm⁴+10.0%
Plastic modulus, major (Wpl,y)23,105.8 cm³23,200 cm³-0.4%
Elastic modulus, major (Wel,y)20,320 cm³19,700 cm³+3.1%
Second moment, minor (Iz)43,288 cm⁴26,700 cm⁴+62.1%
Plastic modulus, minor (Wpl,z)3,359.3 cm³2,800 cm³+20.0%
Radius of gyration, minor (iz)8.86 cm6.57 cm+34.9%
Torsion constant (It)2,119 cm⁴4,300 cm⁴-50.7%

W 44X290 to AISC Shapes Database v16.0; UB 1016×305×487 to BS EN 10365:2017. Difference is expressed relative to UB 1016×305×487.

How to choose between them

On stiffness, W 44X290 has the larger second moment of area: 1,123,825 cm⁴ against 1,022,000 cm⁴, a difference of 10.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, W 44X290 is the more efficient section: 53.5 against 47.7 cm³ per kg/m, 12.3% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: W 44X290 has 3359.3 cm³ of minor-axis plastic modulus against 2800 cm³, 20.0% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and UB to BS EN 10365:2017; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 11.3% weight.

In short, UB 1016×305×487 is the stronger section and W 44X290 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 44X290 has a plastic modulus of 23105.8 cm³ and UB 1016×305×487 has 23200 cm³, a difference of only 0.4% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

W 44X290 at 431.6 kg/m, against 486.7 kg/m for the other - a saving of 11.3%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: UB 1016×305×487 gives 23200 cm³ of plastic modulus and 1,022,000 cm⁴ of inertia against 23105.8 cm³ and 1,123,825 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and BS EN 10365:2017), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

W 44X290, with a second moment of area of 1,123,825 cm⁴ against 1,022,000 cm⁴ (10.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

UB 1016×305×487 vs HE 1000 x 494UB 1016×305×487 vs W 40X327W 44X290 vs HE 1000 x 494W 40X324 vs UB 1016×305×487W 40X331 vs UB 1016×305×487W 36X330 vs UB 1016×305×487W 36X350 vs UB 1016×305×487
Rate this
No ratings yet
Sign in to join the discussion.