CivilAxisCivilAxis
☕ Support🌐 Community

UB 1016×305×487 - Section Properties

The UB 1016×305×487 is a universal beam with a mass of 486.7 kg/m, an overall depth of 1036.3 mm and width of 308.5 mm. It has a cross-sectional area of 620 cm², a second moment of area Iᵧ of 1022000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 23200 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
486.7 kg/m
Depth
1036.3 mm
Width
308.5 mm
Area
620 cm²
Ask about capacity, buckling or detailing for UB 1016×305×487.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 1016×305×487

Dimension symbols for UB sections. Not to scale.

UB 1016×305×487 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh1036.3
Width of sectionb308.5
Web thicknesstw30
Flange thicknesstf54.1
Root fillet radiusr30
Depth between filletsd868.1

Mass and area

Mass per metremass486.7
Cross-sectional areaA620

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1022000
Elastic section modulus about y-axisWel,y19700
Plastic section modulus about y-axisWpl,y23200
Radius of gyration about y-axisiy40.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz26700
Elastic section modulus about z-axisWel,z1730
Plastic section modulus about z-axisWpl,z2800
Radius of gyration about z-axisiz6.57

Torsion and warping

Torsion constant (St Venant)It4300
Warping constantIw64.4

Classification and stability

Flange local-buckling ratiocf/tf2.02
Web local-buckling ratiocw/tw28.9
Buckling parameteru0.867
Torsional indexX21.1

Detailing dimensions

End clearanceC17
Notch dimension NN150
Notch dimension nn86

Surface area

Surface area per metreSA/m3.2
Surface area per tonneSA/t6.58m²/t

Is UB 1016×305×487 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending52%
4320.0 / 8236.0 kNm
Shear21%
1440.0 / 6863.9 kN
Deflection60%
20.1 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 1016×305×487

UB 1016×305×487 has a mass of 486.7 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 5840 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 1016×305×487 has a depth of 1036.3 mm, a width of 308.5 mm, a web thickness of 30 mm, a flange thickness of 54.1 mm, with a cross-sectional area of 620 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 23,200 cm³, and the elastic modulus Wel,y is 19,700 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 8236 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,022,000 cm⁴, and about the minor axis Iz is 26,700 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 2.02 for the flange and cw/tw = 28.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 40.6 cm about the major axis and iz is 6.57 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.57 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,300 cm⁴, and the warping constant Iw is 64.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 1016×305×437UB 1016×305×393UB 1016×305×349UB 1016×305×314UB 1016×305×272UB 1016×305×249UB 1016×305×222UB 914×419×388

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 1000 x 494vs W 40X327vs W 44X290vs W 40X324vs W 40X331vs W 36X330

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…