The UB 1016×305×249 is a universal beam with a mass of 248.7 kg/m, an overall depth of 980.1 mm and width of 300 mm. It has a cross-sectional area of 317 cm², a second moment of area Iᵧ of 481000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 11300 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
248.7 kg/m
Depth
980.1 mm
Width
300 mm
Area
317 cm²
Ask about capacity, buckling or detailing for UB 1016×305×249.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 1016×305×249

Dimension symbols for UB sections. Not to scale.

UB 1016×305×249 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh980.1
Width of sectionb300
Web thicknesstw16.5
Flange thicknesstf26
Root fillet radiusr30
Depth between filletsd868.1

Mass and area

Mass per metremass248.7
Cross-sectional areaA317

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy481000
Elastic section modulus about y-axisWel,y9820
Plastic section modulus about y-axisWpl,y11300
Radius of gyration about y-axisiy39

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz11800
Elastic section modulus about z-axisWel,z784
Plastic section modulus about z-axisWpl,z1240
Radius of gyration about z-axisiz6.09

Torsion and warping

Torsion constant (St Venant)It582
Warping constantIw26.8

Classification and stability

Flange local-buckling ratiocf/tf4.3
Web local-buckling ratiocw/tw52.6
Buckling parameteru0.861
Torsional indexX39.9

Detailing dimensions

End clearanceC10
Notch dimension NN152
Notch dimension nn56

Surface area

Surface area per metreSA/m3.08
Surface area per tonneSA/t12.4m²/t

Is UB 1016×305×249 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending50%
2025.0 / 4011.5 kNm
Shear18%
675.0 / 3707.5 kN
Deflection60%
20.0 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 1016×305×249

UB 1016×305×249 has a mass of 248.7 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2984 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 1016×305×249 has a depth of 980.1 mm, a width of 300 mm, a web thickness of 16.5 mm, a flange thickness of 26 mm, with a cross-sectional area of 317 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 11,300 cm³, and the elastic modulus Wel,y is 9,820 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 4012 kNm before any stability check.

The second moment of area about the major axis, Iy, is 481,000 cm⁴, and about the minor axis Iz is 11,800 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.3 for the flange and cw/tw = 52.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 39 cm about the major axis and iz is 6.09 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.09 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 582 cm⁴, and the warping constant Iw is 26.8 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 1016×305×393UB 1016×305×349UB 1016×305×314UB 1016×305×272UB 1016×305×222UB 914×419×388UB 914×419×343UB 914×305×289

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 1000 x 249vs W 40X167

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…