CivilAxisCivilAxis
☕ Support🌐 Community

UB 914×419×343 - Section Properties

The UB 914×419×343 is a universal beam with a mass of 343.3 kg/m, an overall depth of 911.8 mm and width of 418.5 mm. It has a cross-sectional area of 437 cm², a second moment of area Iᵧ of 626000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 15500 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
343.3 kg/m
Depth
911.8 mm
Width
418.5 mm
Area
437 cm²
Ask about capacity, buckling or detailing for UB 914×419×343.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 914×419×343

Dimension symbols for UB sections. Not to scale.

UB 914×419×343 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh911.8
Width of sectionb418.5
Web thicknesstw19.4
Flange thicknesstf32
Root fillet radiusr24.1
Depth between filletsd799.6

Mass and area

Mass per metremass343.3
Cross-sectional areaA437

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy626000
Elastic section modulus about y-axisWel,y13700
Plastic section modulus about y-axisWpl,y15500
Radius of gyration about y-axisiy37.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz39200
Elastic section modulus about z-axisWel,z1870
Plastic section modulus about z-axisWpl,z2890
Radius of gyration about z-axisiz9.46

Torsion and warping

Torsion constant (St Venant)It1190
Warping constantIw75.8

Classification and stability

Flange local-buckling ratiocf/tf5.48
Web local-buckling ratiocw/tw41.2
Buckling parameteru0.883
Torsional indexX30.1

Detailing dimensions

End clearanceC12
Notch dimension NN210
Notch dimension nn58

Surface area

Surface area per metreSA/m3.42
Surface area per tonneSA/t9.96m²/t

Is UB 914×419×343 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending48%
2619.0 / 5502.5 kNm
Shear22%
873.0 / 3910.5 kN
Deflection60%
19.9 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 914×419×343

UB 914×419×343 has a mass of 343.3 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 4120 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 914×419×343 has a depth of 911.8 mm, a width of 418.5 mm, a web thickness of 19.4 mm, a flange thickness of 32 mm, with a cross-sectional area of 437 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 15,500 cm³, and the elastic modulus Wel,y is 13,700 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 5503 kNm before any stability check.

The second moment of area about the major axis, Iy, is 626,000 cm⁴, and about the minor axis Iz is 39,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.48 for the flange and cw/tw = 41.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 37.8 cm about the major axis and iz is 9.46 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.46 cm a 0.9 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,190 cm⁴, and the warping constant Iw is 75.8 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 1016×305×272UB 1016×305×249UB 1016×305×222UB 914×419×388UB 914×305×289UB 914×305×253UB 914×305×224UB 914×305×201

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 36X231vs W 36X232vs W 33X241

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.