CivilAxisCivilAxis
☕ Support🌐 Community

UB 914×305×224 - Section Properties

The UB 914×305×224 is a universal beam with a mass of 224.2 kg/m, an overall depth of 910.4 mm and width of 304.1 mm. It has a cross-sectional area of 286 cm², a second moment of area Iᵧ of 376000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 9530 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
224.2 kg/m
Depth
910.4 mm
Width
304.1 mm
Area
286 cm²
Ask about capacity, buckling or detailing for UB 914×305×224.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 914×305×224

Dimension symbols for UB sections. Not to scale.

UB 914×305×224 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh910.4
Width of sectionb304.1
Web thicknesstw15.9
Flange thicknesstf23.9
Root fillet radiusr19.1
Depth between filletsd824.4

Mass and area

Mass per metremass224.2
Cross-sectional areaA286

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy376000
Elastic section modulus about y-axisWel,y8270
Plastic section modulus about y-axisWpl,y9530
Radius of gyration about y-axisiy36.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz11200
Elastic section modulus about z-axisWel,z739
Plastic section modulus about z-axisWpl,z1160
Radius of gyration about z-axisiz6.27

Torsion and warping

Torsion constant (St Venant)It422
Warping constantIw22.1

Classification and stability

Flange local-buckling ratiocf/tf5.23
Web local-buckling ratiocw/tw51.8
Buckling parameteru0.86
Torsional indexX41.3

Detailing dimensions

End clearanceC10
Notch dimension NN156
Notch dimension nn44

Surface area

Surface area per metreSA/m2.97
Surface area per tonneSA/t13.2m²/t

Is UB 914×305×224 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending46%
1566.0 / 3383.2 kNm
Shear17%
522.0 / 3147.6 kN
Deflection59%
19.8 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 914×305×224

UB 914×305×224 has a mass of 224.2 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2690 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 914×305×224 has a depth of 910.4 mm, a width of 304.1 mm, a web thickness of 15.9 mm, a flange thickness of 23.9 mm, with a cross-sectional area of 286 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 9,530 cm³, and the elastic modulus Wel,y is 8,270 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 3383 kNm before any stability check.

The second moment of area about the major axis, Iy, is 376,000 cm⁴, and about the minor axis Iz is 11,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.23 for the flange and cw/tw = 51.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 36.3 cm about the major axis and iz is 6.27 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.27 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 422 cm⁴, and the warping constant Iw is 22.1 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 914×419×388UB 914×419×343UB 914×305×289UB 914×305×253UB 914×305×201UB 838×292×226UB 838×292×194UB 838×292×176

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 36X150

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…