UB 914×305×289 - Section Properties

The UB 914×305×289 is a universal beam with a mass of 289.1 kg/m, an overall depth of 926.6 mm and width of 307.7 mm. It has a cross-sectional area of 368 cm², a second moment of area Iᵧ of 504000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 12600 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
289.1 kg/m
Depth
926.6 mm
Width
307.7 mm
Area
368 cm²
Ask about capacity, buckling or detailing for UB 914×305×289.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 914×305×289

Dimension symbols for UB sections. Not to scale.

UB 914×305×289 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh926.6
Width of sectionb307.7
Web thicknesstw19.5
Flange thicknesstf32
Root fillet radiusr19.1
Depth between filletsd824.4

Mass and area

Mass per metremass289.1
Cross-sectional areaA368

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy504000
Elastic section modulus about y-axisWel,y10900
Plastic section modulus about y-axisWpl,y12600
Radius of gyration about y-axisiy37

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz15600
Elastic section modulus about z-axisWel,z1010
Plastic section modulus about z-axisWpl,z1600
Radius of gyration about z-axisiz6.51

Torsion and warping

Torsion constant (St Venant)It926
Warping constantIw31.2

Classification and stability

Flange local-buckling ratiocf/tf3.91
Web local-buckling ratiocw/tw42.3
Buckling parameteru0.867
Torsional indexX31.9

Detailing dimensions

End clearanceC12
Notch dimension NN156
Notch dimension nn52

Surface area

Surface area per metreSA/m3.01
Surface area per tonneSA/t10.4m²/t

Is UB 914×305×289 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending47%
2106.0 / 4473.0 kNm
Shear18%
702.0 / 3884.7 kN
Deflection60%
19.9 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 914×305×289

UB 914×305×289 has a mass of 289.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 3469 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 914×305×289 has a depth of 926.6 mm, a width of 307.7 mm, a web thickness of 19.5 mm, a flange thickness of 32 mm, with a cross-sectional area of 368 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 12,600 cm³, and the elastic modulus Wel,y is 10,900 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 4473 kNm before any stability check.

The second moment of area about the major axis, Iy, is 504,000 cm⁴, and about the minor axis Iz is 15,600 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.91 for the flange and cw/tw = 42.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 37 cm about the major axis and iz is 6.51 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.51 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 926 cm⁴, and the warping constant Iw is 31.2 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 1016×305×249UB 1016×305×222UB 914×419×388UB 914×419×343UB 914×305×253UB 914×305×224UB 914×305×201UB 838×292×226

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 900 Bvs W 36X194vs H-900x300x18x34-286vs W 33X201

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…