CivilAxisCivilAxis
☕ Support🌐 Community

UB 914×305×253 - Section Properties

The UB 914×305×253 is a universal beam with a mass of 253.4 kg/m, an overall depth of 918.4 mm and width of 305.5 mm. It has a cross-sectional area of 323 cm², a second moment of area Iᵧ of 436000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 10900 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
253.4 kg/m
Depth
918.4 mm
Width
305.5 mm
Area
323 cm²
Ask about capacity, buckling or detailing for UB 914×305×253.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 914×305×253

Dimension symbols for UB sections. Not to scale.

UB 914×305×253 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh918.4
Width of sectionb305.5
Web thicknesstw17.3
Flange thicknesstf27.9
Root fillet radiusr19.1
Depth between filletsd824.4

Mass and area

Mass per metremass253.4
Cross-sectional areaA323

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy436000
Elastic section modulus about y-axisWel,y9500
Plastic section modulus about y-axisWpl,y10900
Radius of gyration about y-axisiy36.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz13300
Elastic section modulus about z-axisWel,z871
Plastic section modulus about z-axisWpl,z1370
Radius of gyration about z-axisiz6.42

Torsion and warping

Torsion constant (St Venant)It626
Warping constantIw26.4

Classification and stability

Flange local-buckling ratiocf/tf4.48
Web local-buckling ratiocw/tw47.7
Buckling parameteru0.865
Torsional indexX36.2

Detailing dimensions

End clearanceC11
Notch dimension NN156
Notch dimension nn48

Surface area

Surface area per metreSA/m2.99
Surface area per tonneSA/t11.8m²/t

Is UB 914×305×253 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending47%
1836.0 / 3869.5 kNm
Shear18%
612.0 / 3443.6 kN
Deflection60%
20.1 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 914×305×253

UB 914×305×253 has a mass of 253.4 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 3041 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 914×305×253 has a depth of 918.4 mm, a width of 305.5 mm, a web thickness of 17.3 mm, a flange thickness of 27.9 mm, with a cross-sectional area of 323 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 10,900 cm³, and the elastic modulus Wel,y is 9,500 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 3870 kNm before any stability check.

The second moment of area about the major axis, Iy, is 436,000 cm⁴, and about the minor axis Iz is 13,300 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.48 for the flange and cw/tw = 47.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 36.8 cm about the major axis and iz is 6.42 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.42 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 626 cm⁴, and the warping constant Iw is 26.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 1016×305×222UB 914×419×388UB 914×419×343UB 914×305×289UB 914×305×224UB 914×305×201UB 838×292×226UB 838×292×194

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 900 Avs W 36X170vs H-900x300x16x28-243

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…