HE 600 x 399 - Section Properties

The HE 600 x 399 is a European wide-flange beam (HE) with a mass of 399 kg/m, an overall depth of 648 mm and width of 315 mm. It has a cross-sectional area of 508 cm², a second moment of area Iᵧ of 345000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 12500 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
399 kg/m
Depth
648 mm
Width
315 mm
Area
508 cm²
Ask about capacity, buckling or detailing for HE 600 x 399.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 600 x 399

Dimension symbols for HE sections. Not to scale.

HE 600 x 399 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh648
Width of sectionb315
Web thicknesstw30
Flange thicknesstf54
Root fillet radiusr27
Depth between filletsd486

Mass and area

Mass per metremass399
Cross-sectional areaA508

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy345000
Elastic section modulus about y-axisWel,y10600
Plastic section modulus about y-axisWpl,y12500
Radius of gyration about y-axisiy26

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz28300
Elastic section modulus about z-axisWel,z1800
Plastic section modulus about z-axisWpl,z2810
Radius of gyration about z-axisiz7.46

Torsion and warping

Torsion constant (St Venant)It3930
Warping constantIw24.8

Classification and stability

Flange local-buckling ratiocf/tf2.14
Web local-buckling ratiocw/tw16.2
Buckling parameteru8.201
Torsional indexX12

Detailing dimensions

End clearanceC17
Notch dimension NN154
Notch dimension nn82

Surface area

Surface area per metreSA/m2.45

Is HE 600 x 399 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending33%
1458.0 / 4437.5 kNm
Shear11%
486.0 / 4368.9 kN
Deflection60%
20.1 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 600 x 399

HE 600 x 399 has a mass of 399 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 4788 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 600 x 399 has a depth of 648 mm, a width of 315 mm, a web thickness of 30 mm, a flange thickness of 54 mm, with a cross-sectional area of 508 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 12,500 cm³, and the elastic modulus Wel,y is 10,600 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 4438 kNm before any stability check.

The second moment of area about the major axis, Iy, is 345,000 cm⁴, and about the minor axis Iz is 28,300 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 2.14 for the flange and cw/tw = 16.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 26 cm about the major axis and iz is 7.46 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.46 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3,930 cm⁴, and the warping constant Iw is 24.8 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 600 AHE 600 BHE 600 MHE 600 x 337HE 650 AAHE 650 AHE 650 BHE 650 M

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 24X250vs W 21X275

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…