CivilAxisCivilAxis
☕ Support🌐 Community

HE 650 AA - Section Properties

The HE 650 AA is a European wide-flange beam (HE) with a mass of 138 kg/m, an overall depth of 620 mm and width of 300 mm. It has a cross-sectional area of 176 cm², a second moment of area Iᵧ of 114000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4160 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
138 kg/m
Depth
620 mm
Width
300 mm
Area
176 cm²
Ask about capacity, buckling or detailing for HE 650 AA.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 650 AA

Dimension symbols for HE sections. Not to scale.

HE 650 AA section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh620
Width of sectionb300
Web thicknesstw12.5
Flange thicknesstf16
Root fillet radiusr27
Depth between filletsd534

Mass and area

Mass per metremass138
Cross-sectional areaA176

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy114000
Elastic section modulus about y-axisWel,y3680
Plastic section modulus about y-axisWpl,y4160
Radius of gyration about y-axisiy25.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7220
Elastic section modulus about z-axisWel,z481
Plastic section modulus about z-axisWpl,z751
Radius of gyration about z-axisiz6.41

Torsion and warping

Torsion constant (St Venant)It158
Warping constantIw6.57

Classification and stability

Flange local-buckling ratiocf/tf7.3
Web local-buckling ratiocw/tw42.7
Buckling parameteru7.594
Torsional indexX35.9

Detailing dimensions

End clearanceC8
Notch dimension NN154
Notch dimension nn44

Surface area

Surface area per metreSA/m2.37

Is HE 650 AA strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
486.0 / 1476.8 kNm
Shear9%
162.0 / 1857.8 kN
Deflection61%
20.3 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 650 AA

HE 650 AA has a mass of 138 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 1656 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 650 AA has a depth of 620 mm, a width of 300 mm, a web thickness of 12.5 mm, a flange thickness of 16 mm, with a cross-sectional area of 176 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,160 cm³, and the elastic modulus Wel,y is 3,680 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1477 kNm before any stability check.

The second moment of area about the major axis, Iy, is 114,000 cm⁴, and about the minor axis Iz is 7,220 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.3 for the flange and cw/tw = 42.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 25.5 cm about the major axis and iz is 6.41 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.41 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 158 cm⁴, and the warping constant Iw is 6.57 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 600 BHE 600 MHE 600 x 337HE 600 x 399HE 650 AHE 650 BHE 650 MHE 650 x 343

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 610×229×140vs W 24X94

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…