H-250x175x7x11-43.6 - Section Properties

The H-250x175x7x11-43.6 is a European narrow I-beam with a mass of 43.6 kg/m, an overall depth of 244 mm and width of 175 mm. It has a cross-sectional area of 55.5 cm², a second moment of area Iᵧ of 6037 cm⁴, a plastic modulus Wₚₗ,ᵧ of 550 cm³, tabulated by CivilAxis from Continental Steel.

Mass
43.6 kg/m
Depth
244 mm
Width
175 mm
Area
55.5 cm²
Ask about capacity, buckling or detailing for H-250x175x7x11-43.6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-250x175x7x11-43.6

Dimension symbols for MB & MC sections. Not to scale.

H-250x175x7x11-43.6 section properties to Continental Steel.

Geometry

Depth of sectionh244
Width of sectionb175
Web thicknesstw7
Flange thicknesstf11
Root fillet radiusr13
Depth between filletsd196

Mass and area

Mass per metremass43.6
Cross-sectional areaA55.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy6037
Elastic section modulus about y-axisWel,y495
Plastic section modulus about y-axisWpl,y550
Radius of gyration about y-axisiy10.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz984
Elastic section modulus about z-axisWel,z112
Plastic section modulus about z-axisWpl,z172
Radius of gyration about z-axisiz4.21

Torsion and warping

Torsion constant (St Venant)It21.2
Warping constantIw0.134

Classification and stability

Flange local-buckling ratiocf/tf7.95
Web local-buckling ratiocw/tw28
Buckling parameteru0.883
Torsional indexX21.3

Detailing dimensions

End clearanceC6
Notch dimension NN94
Notch dimension nn24

Surface area

Surface area per metreSA/m1.15

Is H-250x175x7x11-43.6 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
60.9 / 195.3 kNm
Shear12%
48.8 / 422.8 kN
Deflection60%
8.3 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-250x175x7x11-43.6

H-250x175x7x11-43.6 has a mass of 43.6 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 523 kg, which is the figure to use for a steel take-off or when checking a lift.

H-250x175x7x11-43.6 has a depth of 244 mm, a width of 175 mm, a web thickness of 7 mm, a flange thickness of 11 mm, with a cross-sectional area of 55.5 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 550 cm³, and the elastic modulus Wel,y is 495 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 195 kNm before any stability check.

The second moment of area about the major axis, Iy, is 6,037 cm⁴, and about the minor axis Iz is 984 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.95 for the flange and cw/tw = 28 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.4 cm about the major axis and iz is 4.21 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.21 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 21.2 cm⁴, and the warping constant Iw is 0.134 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-250x125x5x8-25.1H-250x125x5x8-25.7H-250x125x6x9-29H-250x125x6x9-29.6H-250x175x7x11-44.1H-250x175x8x13H-250x175x9x15H-250x250x8x13

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…