CivilAxisCivilAxis
☕ Support🌐 Community

H-250x125x5x8-25.1 - Section Properties

The H-250x125x5x8-25.1 is a European narrow I-beam with a mass of 25.1 kg/m, an overall depth of 248 mm and width of 124 mm. It has a cross-sectional area of 32 cm², a second moment of area Iᵧ of 3450 cm⁴, a plastic modulus Wₚₗ,ᵧ of 312 cm³, tabulated by CivilAxis from Continental Steel.

Mass
25.1 kg/m
Depth
248 mm
Width
124 mm
Area
32 cm²
Ask about capacity, buckling or detailing for H-250x125x5x8-25.1.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-250x125x5x8-25.1

Dimension symbols for MB & MC sections. Not to scale.

H-250x125x5x8-25.1 section properties to Continental Steel.

Geometry

Depth of sectionh248
Width of sectionb124
Web thicknesstw5
Flange thicknesstf8
Root fillet radiusr8
Depth between filletsd216

Mass and area

Mass per metremass25.1
Cross-sectional areaA32

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3450
Elastic section modulus about y-axisWel,y278
Plastic section modulus about y-axisWpl,y312
Radius of gyration about y-axisiy10.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz255
Elastic section modulus about z-axisWel,z41.1
Plastic section modulus about z-axisWpl,z63.2
Radius of gyration about z-axisiz2.82

Torsion and warping

Torsion constant (St Venant)It5.78
Warping constantIw0.037

Classification and stability

Flange local-buckling ratiocf/tf7.75
Web local-buckling ratiocw/tw43.2
Buckling parameteru0.884
Torsional indexX32

Detailing dimensions

End clearanceC5
Notch dimension NN70
Notch dimension nn16

Surface area

Surface area per metreSA/m0.968

Is H-250x125x5x8-25.1 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
35.2 / 110.8 kNm
Shear10%
28.1 / 283.7 kN
Deflection61%
8.4 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-250x125x5x8-25.1

H-250x125x5x8-25.1 has a mass of 25.1 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 301 kg, which is the figure to use for a steel take-off or when checking a lift.

H-250x125x5x8-25.1 has a depth of 248 mm, a width of 124 mm, a web thickness of 5 mm, a flange thickness of 8 mm, with a cross-sectional area of 32 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 312 cm³, and the elastic modulus Wel,y is 278 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 111 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,450 cm⁴, and about the minor axis Iz is 255 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.75 for the flange and cw/tw = 43.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.4 cm about the major axis and iz is 2.82 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.82 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5.78 cm⁴, and the warping constant Iw is 0.037 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-200x200x6.5x10H-200x200x8x12H-200x200x9x14H-200x200x10x16H-250x125x5x8-25.7H-250x125x6x9-29H-250x125x6x9-29.6H-250x175x7x11-43.6

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 254×102×25vs W 10X17

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…