H-250x125x6x9-29.6 - Section Properties

The H-250x125x6x9-29.6 is a European narrow I-beam with a mass of 29.6 kg/m, an overall depth of 250 mm and width of 125 mm. It has a cross-sectional area of 37.7 cm², a second moment of area Iᵧ of 4052 cm⁴, a plastic modulus Wₚₗ,ᵧ of 366 cm³, tabulated by CivilAxis from Continental Steel.

Mass
29.6 kg/m
Depth
250 mm
Width
125 mm
Area
37.7 cm²
Ask about capacity, buckling or detailing for H-250x125x6x9-29.6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-250x125x6x9-29.6

Dimension symbols for MB & MC sections. Not to scale.

H-250x125x6x9-29.6 section properties to Continental Steel.

Geometry

Depth of sectionh250
Width of sectionb125
Web thicknesstw6
Flange thicknesstf9
Root fillet radiusr12
Depth between filletsd208

Mass and area

Mass per metremass29.6
Cross-sectional areaA37.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4052
Elastic section modulus about y-axisWel,y324
Plastic section modulus about y-axisWpl,y366
Radius of gyration about y-axisiy10.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz294
Elastic section modulus about z-axisWel,z47
Plastic section modulus about z-axisWpl,z73.1
Radius of gyration about z-axisiz2.79

Torsion and warping

Torsion constant (St Venant)It9.68
Warping constantIw0.043

Classification and stability

Flange local-buckling ratiocf/tf6.94
Web local-buckling ratiocw/tw34.7
Buckling parameteru0.881
Torsional indexX26.9

Detailing dimensions

End clearanceC5
Notch dimension NN70
Notch dimension nn21

Surface area

Surface area per metreSA/m0.967

Is H-250x125x6x9-29.6 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
39.8 / 129.9 kNm
Shear9%
31.9 / 366.9 kN
Deflection59%
8.1 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-250x125x6x9-29.6

H-250x125x6x9-29.6 has a mass of 29.6 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 355 kg, which is the figure to use for a steel take-off or when checking a lift.

H-250x125x6x9-29.6 has a depth of 250 mm, a width of 125 mm, a web thickness of 6 mm, a flange thickness of 9 mm, with a cross-sectional area of 37.7 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 366 cm³, and the elastic modulus Wel,y is 324 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 130 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,052 cm⁴, and about the minor axis Iz is 294 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.94 for the flange and cw/tw = 34.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.4 cm about the major axis and iz is 2.79 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.79 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9.68 cm⁴, and the warping constant Iw is 0.043 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-200x200x10x16H-250x125x5x8-25.1H-250x125x5x8-25.7H-250x125x6x9-29H-250x175x7x11-43.6H-250x175x7x11-44.1H-250x175x8x13H-250x175x9x15

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 240

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…