CivilAxisCivilAxis
☕ Support🌐 Community

PFC 200×75×23 - Section Properties

The PFC 200×75×23 is a parallel flange channel with a mass of 23.4 kg/m, an overall depth of 200 mm and width of 75 mm. It has a cross-sectional area of 29.9 cm², a second moment of area Iᵧ of 1960 cm⁴, a plastic modulus Wₚₗ,ᵧ of 227 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
23.4 kg/m
Depth
200 mm
Width
75 mm
Area
29.9 cm²
Ask about capacity, buckling or detailing for PFC 200×75×23.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 200×75×23

Dimension symbols for PFC sections. Not to scale.

PFC 200×75×23 section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Geometry

Depth of sectionh200
Width of sectionb75
Web thicknesstw6
Flange thicknesstf12.5
Root fillet radiusr12
Depth between filletsd151

Mass and area

Mass per metremass23.4
Cross-sectional areaA29.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1960
Elastic section modulus about y-axisWel,y196
Plastic section modulus about y-axisWpl,y227
Radius of gyration about y-axisiy8.11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz170
Elastic section modulus about z-axisWel,z33.8
Plastic section modulus about z-axisWpl,z60.6
Radius of gyration about z-axisiz2.39

Torsion and warping

Torsion constant (St Venant)It11.1
Warping constantIw0.0107

Classification and stability

Flange local-buckling ratiocf/tf4.56
Web local-buckling ratiocw/tw25.2
Buckling parameteru0.956
Torsional indexX14.7

Detailing dimensions

End clearanceC8
Notch dimension NN76
Notch dimension nn26
Distance from web face to flange tipe02.91

Surface area

Surface area per metreSA/m0.678
Surface area per tonneSA/t28.9m²/t

Is PFC 200×75×23 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending30%
24.0 / 80.6 kNm
Shear9%
24.0 / 274.6 kN
Deflection58%
6.5 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 200×75×23

PFC 200×75×23 has a mass of 23.4 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 281 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 200×75×23 has a depth of 200 mm, a width of 75 mm, a web thickness of 6 mm, a flange thickness of 12.5 mm, with a cross-sectional area of 29.9 cm². These are the nominal dimensions from BS EN 1993-1-1:2005 / BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 227 cm³, and the elastic modulus Wel,y is 196 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 81 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,960 cm⁴, and about the minor axis Iz is 170 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.56 for the flange and cw/tw = 25.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.11 cm about the major axis and iz is 2.39 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.39 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 11.1 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 260×75×28PFC 230×90×32PFC 230×75×26PFC 200×90×30PFC 180×90×26PFC 180×75×20PFC 150×90×24PFC 150×75×18

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 200×75vs C 8X18.75

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…