CivilAxisCivilAxis
☕ Support🌐 Community

PFC 200×90×30 - Section Properties

The PFC 200×90×30 is a parallel flange channel with a mass of 29.7 kg/m, an overall depth of 200 mm and width of 90 mm. It has a cross-sectional area of 37.9 cm², a second moment of area Iᵧ of 2520 cm⁴, a plastic modulus Wₚₗ,ᵧ of 291 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
29.7 kg/m
Depth
200 mm
Width
90 mm
Area
37.9 cm²
Ask about capacity, buckling or detailing for PFC 200×90×30.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 200×90×30

Dimension symbols for PFC sections. Not to scale.

PFC 200×90×30 section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Geometry

Depth of sectionh200
Width of sectionb90
Web thicknesstw7
Flange thicknesstf14
Root fillet radiusr12
Depth between filletsd148

Mass and area

Mass per metremass29.7
Cross-sectional areaA37.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2520
Elastic section modulus about y-axisWel,y252
Plastic section modulus about y-axisWpl,y291
Radius of gyration about y-axisiy8.16

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz314
Elastic section modulus about z-axisWel,z53.4
Plastic section modulus about z-axisWpl,z94.5
Radius of gyration about z-axisiz2.88

Torsion and warping

Torsion constant (St Venant)It18.3
Warping constantIw0.0197

Classification and stability

Flange local-buckling ratiocf/tf5.07
Web local-buckling ratiocw/tw21.1
Buckling parameteru0.952
Torsional indexX12.9

Detailing dimensions

End clearanceC9
Notch dimension NN90
Notch dimension nn28
Distance from web face to flange tipe03.6

Surface area

Surface area per metreSA/m0.736
Surface area per tonneSA/t24.8m²/t

Is PFC 200×90×30 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending32%
33.0 / 103.3 kNm
Shear10%
33.0 / 314.8 kN
Deflection62%
6.9 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 200×90×30

PFC 200×90×30 has a mass of 29.7 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 356 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 200×90×30 has a depth of 200 mm, a width of 90 mm, a web thickness of 7 mm, a flange thickness of 14 mm, with a cross-sectional area of 37.9 cm². These are the nominal dimensions from BS EN 1993-1-1:2005 / BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 291 cm³, and the elastic modulus Wel,y is 252 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 103 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,520 cm⁴, and about the minor axis Iz is 314 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.07 for the flange and cw/tw = 21.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.16 cm about the major axis and iz is 2.88 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.88 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 18.3 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 260×90×35PFC 260×75×28PFC 230×90×32PFC 230×75×26PFC 200×75×23PFC 180×90×26PFC 180×75×20PFC 150×90×24

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 200×90vs MC 8X21.4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…