CivilAxisCivilAxis
☕ Support🌐 Community

PFC 230×75×26 - Section Properties

The PFC 230×75×26 is a parallel flange channel with a mass of 25.7 kg/m, an overall depth of 230 mm and width of 75 mm. It has a cross-sectional area of 32.7 cm², a second moment of area Iᵧ of 2750 cm⁴, a plastic modulus Wₚₗ,ᵧ of 278 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
25.7 kg/m
Depth
230 mm
Width
75 mm
Area
32.7 cm²
Ask about capacity, buckling or detailing for PFC 230×75×26.
🔍 Open the full Steel Catalogue →📖 Design theory📐 Worked example
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 230×75×26

Dimension symbols for PFC sections. Not to scale.

PFC 230×75×26 section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Geometry

Depth of sectionh230
Width of sectionb75
Web thicknesstw6.5
Flange thicknesstf12.5
Root fillet radiusr12
Depth between filletsd181

Mass and area

Mass per metremass25.7
Cross-sectional areaA32.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2750
Elastic section modulus about y-axisWel,y239
Plastic section modulus about y-axisWpl,y278
Radius of gyration about y-axisiy9.17

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz181
Elastic section modulus about z-axisWel,z34.8
Plastic section modulus about z-axisWpl,z63.2
Radius of gyration about z-axisiz2.35

Torsion and warping

Torsion constant (St Venant)It11.8
Warping constantIw0.0153

Classification and stability

Flange local-buckling ratiocf/tf4.52
Web local-buckling ratiocw/tw27.8
Buckling parameteru0.945
Torsional indexX17.3

Detailing dimensions

End clearanceC9
Notch dimension NN76
Notch dimension nn26
Distance from web face to flange tipe02.78

Surface area

Surface area per metreSA/m0.737
Surface area per tonneSA/t28.7m²/t

Is PFC 230×75×26 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

✅Passes - 59% utilised, deflection governs
Bending31%
30.4 / 98.7 kNm
Shear8%
27.0 / 333.3 kN
Deflection59%
7.4 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 230×75×26

PFC 230×75×26 has a mass of 25.7 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 308 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 230×75×26 has a depth of 230 mm, a width of 75 mm, a web thickness of 6.5 mm, a flange thickness of 12.5 mm, with a cross-sectional area of 32.7 cm². These are the nominal dimensions from BS EN 1993-1-1:2005 / BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 278 cm³, and the elastic modulus Wel,y is 239 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 99 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,750 cm⁴, and about the minor axis Iz is 181 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.52 for the flange and cw/tw = 27.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.17 cm about the major axis and iz is 2.35 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.35 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 11.8 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 300×90×41PFC 260×90×35PFC 260×75×28PFC 230×90×32PFC 200×90×30PFC 200×75×23PFC 180×90×26PFC 180×75×20

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 230×75 →vs C 9X20 →

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE) →📘 Section modulus explained: elastic (Wel) vs plastic (Wpl) →
All PFC sizes →
Parallel Flange Channels (PFC)
Full steel section tables →
Every UB, UC, hollow, channel & angle section
Open the interactive tool →
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…