CivilAxisCivilAxis
☕ Support🌐 Community

CF RHS 500×300×6 - Section Properties

The CF RHS 500×300×6 is a rectangular hollow section with a mass of 73.5 kg/m, an overall depth of 500 mm and width of 300 mm and a wall thickness of 6 mm. It has a cross-sectional area of 93.6 cm², a second moment of area Iᵧ of 33000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1580 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
73.5 kg/m
Depth
500 mm
Width
300 mm
Wall thickness
6 mm
Area
93.6 cm²
Ask about capacity, buckling or detailing for CF RHS 500×300×6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for CF RHS 500×300×6

Dimension symbols for RHS Cold-formed sections. Not to scale.

CF RHS 500×300×6 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh500
Width of sectionb300
Wall thicknesst6

Mass and area

Mass per metremass73.5
Cross-sectional areaA93.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy33000
Elastic section modulus about y-axisWel,y1320
Plastic section modulus about y-axisWpl,y1580
Radius of gyration about y-axisiy18.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz15200
Elastic section modulus about z-axisWel,z1010
Plastic section modulus about z-axisWpl,z1120
Radius of gyration about z-axisiz12.7

Torsion and warping

Torsion constant (St Venant)It32400
Section modulus for torsionWt1690

Classification and stability

Flange local-buckling ratiocf/tf47
Web local-buckling ratiocw/tw80.3

Surface area

Surface area per metreSA/m1.58
Surface area per tonneSA/t21.5m²/t

Common questions about CF RHS 500×300×6

CF RHS 500×300×6 has a mass of 73.5 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 882 kg, which is the figure to use for a steel take-off or when checking a lift.

CF RHS 500×300×6 has a depth of 500 mm, a width of 300 mm, a wall thickness of 6 mm, with a cross-sectional area of 93.6 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,580 cm³, and the elastic modulus Wel,y is 1,320 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 561 kNm before any stability check.

The second moment of area about the major axis, Iy, is 33,000 cm⁴, and about the minor axis Iz is 15,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 47 for the flange and cw/tw = 80.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.8 cm about the major axis and iz is 12.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 12.7 cm a 1.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 32,400 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

CF RHS 450×250×8CF RHS 450×250×10CF RHS 450×250×12CF RHS 450×250×12.5CF RHS 500×300×6.3CF RHS 500×300×8CF RHS 500×300×10CF RHS 500×300×12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…