CivilAxisCivilAxis
☕ Support🌐 Community

CF RHS 500×300×8 - Section Properties

The CF RHS 500×300×8 is a rectangular hollow section with a mass of 96.7 kg/m, an overall depth of 500 mm and width of 300 mm and a wall thickness of 8 mm. It has a cross-sectional area of 123 cm², a second moment of area Iᵧ of 42800 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2060 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
96.7 kg/m
Depth
500 mm
Width
300 mm
Wall thickness
8 mm
Area
123 cm²
Ask about capacity, buckling or detailing for CF RHS 500×300×8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for CF RHS 500×300×8

Dimension symbols for RHS Cold-formed sections. Not to scale.

CF RHS 500×300×8 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh500
Width of sectionb300
Wall thicknesst8

Mass and area

Mass per metremass96.7
Cross-sectional areaA123

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy42800
Elastic section modulus about y-axisWel,y1710
Plastic section modulus about y-axisWpl,y2060
Radius of gyration about y-axisiy18.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz19600
Elastic section modulus about z-axisWel,z1310
Plastic section modulus about z-axisWpl,z1460
Radius of gyration about z-axisiz12.6

Torsion and warping

Torsion constant (St Venant)It42800
Section modulus for torsionWt2200

Classification and stability

Flange local-buckling ratiocf/tf34.5
Web local-buckling ratiocw/tw59.5

Surface area

Surface area per metreSA/m1.57
Surface area per tonneSA/t16.2m²/t

Common questions about CF RHS 500×300×8

CF RHS 500×300×8 has a mass of 96.7 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 1160 kg, which is the figure to use for a steel take-off or when checking a lift.

CF RHS 500×300×8 has a depth of 500 mm, a width of 300 mm, a wall thickness of 8 mm, with a cross-sectional area of 123 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,060 cm³, and the elastic modulus Wel,y is 1,710 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 731 kNm before any stability check.

The second moment of area about the major axis, Iy, is 42,800 cm⁴, and about the minor axis Iz is 19,600 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 34.5 for the flange and cw/tw = 59.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.6 cm about the major axis and iz is 12.6 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 12.6 cm a 1.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 42,800 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

CF RHS 450×250×10CF RHS 450×250×12CF RHS 450×250×12.5CF RHS 500×300×6CF RHS 500×300×6.3CF RHS 500×300×10CF RHS 500×300×12CF RHS 500×300×12.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…