CF RHS 50×30×2.5 - Section Properties
The CF RHS 50×30×2.5 is a rectangular hollow section with a mass of 2.82 kg/m, an overall depth of 50 mm and width of 30 mm and a wall thickness of 2.5 mm. It has a cross-sectional area of 3.59 cm², a second moment of area Iᵧ of 11.3 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5.7 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 50×30×2.5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 50×30×2.5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending28%
0.6 / 2.0 kNmShear5%
2.3 / 46.0 kNDeflection59%
1.6 / 2.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF RHS 50×30×2.5
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.