RND 200 - Section Properties

The RND 200 is a steel section with a mass of 246.62 kg/m, an overall width of 200 mm. It has a cross-sectional area of 314.2 cm², a second moment of area Iᵧ of 7854 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1333 cm³, tabulated by CivilAxis from EN 10058 · Continental Steel.

Mass
246.62 kg/m
Diameter
200 mm
Area
314.2 cm²
Ask about capacity, buckling or detailing for RND 200.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RND 200 section properties to EN 10058 · Continental Steel.

Geometry

Width of sectionb200

Mass and area

Mass per metremass246.62
Cross-sectional areaA314.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7854
Elastic section modulus about y-axisWel,y785.4
Plastic section modulus about y-axisWpl,y1333
Radius of gyration about y-axisiy5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7854
Elastic section modulus about z-axisWel,z785.4
Plastic section modulus about z-axisWpl,z1333
Radius of gyration about z-axisiz5

Common questions about RND 200

RND 200 has a mass of 246.62 kg/m, tabulated to EN 10058. A 12 m length therefore weighs about 2959 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 1,333 cm³, and the elastic modulus Wel,y is 785.4 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 473 kNm before any stability check.

The second moment of area about the major axis, Iy, is 7,854 cm⁴, and about the minor axis Iz is 7,854 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5 cm about the major axis and iz is 5 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Round Bar sizes

RND 50RND 60RND 65RND 75RND 90RND 100RND 125RND 150

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Round Bar sizes
Round Bars
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…