CF SHS 120×120×6 - Section Properties
The CF SHS 120×120×6 is a square hollow section with a mass of 20.7 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 6 mm. It has a cross-sectional area of 26.4 cm², a second moment of area Iᵧ of 562 cm⁴, a plastic modulus Wₚₗ,ᵧ of 112 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF SHS 120×120×6.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is CF SHS 120×120×6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending28%
11.1 / 39.8 kNmShear7%
17.8 / 270.5 kNDeflection59%
4.1 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF SHS 120×120×6
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet