CivilAxisCivilAxis
☕ Support🌐 Community

CF SHS 120×120×5 - Section Properties

The CF SHS 120×120×5 is a square hollow section with a mass of 17.5 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 5 mm. It has a cross-sectional area of 22.4 cm², a second moment of area Iᵧ of 485 cm⁴, a plastic modulus Wₚₗ,ᵧ of 95.4 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
17.5 kg/m
Depth
120 mm
Width
120 mm
Wall thickness
5 mm
Area
22.4 cm²
Ask about capacity, buckling or detailing for CF SHS 120×120×5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 120×120×5

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 120×120×5 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh120
Width of sectionb120
Wall thicknesst5

Mass and area

Mass per metremass17.5
Cross-sectional areaA22.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy485
Elastic section modulus about y-axisWel,y80.9
Plastic section modulus about y-axisWpl,y95.4
Radius of gyration about y-axisiy4.66

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz485
Elastic section modulus about z-axisWel,z80.9
Plastic section modulus about z-axisWpl,z95.4
Radius of gyration about z-axisiz4.66

Torsion and warping

Torsion constant (St Venant)It778
Section modulus for torsionWt122

Surface area

Surface area per metreSA/m0.463
Surface area per tonneSA/t26.4m²/t

Is CF SHS 120×120×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending29%
10.0 / 33.9 kNm
Shear7%
15.9 / 229.6 kN
Deflection61%
4.2 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 120×120×5

CF SHS 120×120×5 has a mass of 17.5 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 210 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 120×120×5 has a depth of 120 mm, a width of 120 mm, a wall thickness of 5 mm, with a cross-sectional area of 22.4 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 95.4 cm³, and the elastic modulus Wel,y is 80.9 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 34 kNm before any stability check.

The second moment of area about the major axis, Iy, is 485 cm⁴, and about the minor axis Iz is 485 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.66 cm about the major axis and iz is 4.66 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.66 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 778 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 100×100×6CF SHS 100×100×8CF SHS 120×120×3CF SHS 120×120×4CF SHS 120×120×6CF SHS 120×120×8CF SHS 120×120×10CF SHS 140×140×4

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 120×120×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.